Product Details | POWER TRANSFORMER

5950-00-450-3435 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station

Part Alternates: 243154P2, 5950-00-450-3435, 00-450-3435, 5950004503435, 004503435

Electrical and Electronic Equipment Components | Coils and Transformers

Supply Group (FSG) NSN Assign. NIIN
59 19 FEB 1972 00-450-3435

Cross Reference | NSN 5950-00-450-3435

Part Number Cage Code Manufacturer
243154P2 94117 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5950-00-450-3435

Technical Data | NSN 5950-00-450-3435

Characteristic Specifications
TERMINAL TYPE AND QUANTITY 14 TURRET
WINDING OPERATING VOLTAGE 1067.00 AC VOLTS MINIMUM AND 1133.00 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY 87.30 AC VOLTS MINIMUM AND 92.70 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY 1891.50 AC VOLTS MINIMUM AND 1008.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY 87.30 AC VOLTS MINIMUM AND 92.70 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY 113.00 AC VOLTS MINIMUM AND 195.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY
WINDING OPERATING CURRENT 10.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 15.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY
FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT
WINDING FUNCTION AND QUANTITY 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT
INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT
MOUNTING METHOD FLANGE AND UNTHREADED HOLE SINGLE GROUP
MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
MOUNTING HOLE DIAMETER 0.165 INCHES MINIMUM AND 0.175 INCHES MAXIMUM SINGLE GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH 2.820 INCHES MAXIMUM
BODY HEIGHT 1.160 INCHES MAXIMUM
BODY WIDTH 2.250 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
III TRANSFORMER WINDING CONNECTION TYPE DELTA-WYE
III MAXIMUM OPERATING TEMP 155.0 DEG CELSIUS
(NON-CORE DATA) CUBIC MEASURE 7.4 CUBIC INCHES

Restrictions/Controls & Freight Information | NSN 5950-00-450-3435

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 063420 TRANSFORMERS,NOI,OR TRANSFORMER PAR
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 595 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5950-00-450-3435

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each