NSN 5950-00-450-3435 243154P2, 00-450-3435, 004503435
Product Details | POWER TRANSFORMER
5950-00-450-3435 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.20259500022Coils and Transformers61200044Transformers: Distribution and Power Station
Part Alternates: 243154P2, 5950-00-450-3435, 00-450-3435, 5950004503435, 004503435
Electrical and Electronic Equipment Components | Coils and Transformers
Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | 19 FEB 1972 | 00-450-3435 | 32496 ( TRANSFORMER, POWER ) |
Cross Reference | NSN 5950-00-450-3435
Part Number | Cage Code | Manufacturer |
---|---|---|
243154P2 | 94117 | BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION INC. |
Request a Quote
What Our Customers Say
Compare
Related Products | NSN 5950-00-450-3435
Technical Data | NSN 5950-00-450-3435
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 14 TURRET |
WINDING OPERATING VOLTAGE | 1067.00 AC VOLTS MINIMUM AND 1133.00 AC VOLTS MAXIMUM SINGLE COMPONENT 1ST SECONDARY 87.30 AC VOLTS MINIMUM AND 92.70 AC VOLTS MAXIMUM SINGLE COMPONENT 2ND SECONDARY 1891.50 AC VOLTS MINIMUM AND 1008.50 AC VOLTS MAXIMUM SINGLE COMPONENT 3RD SECONDARY 87.30 AC VOLTS MINIMUM AND 92.70 AC VOLTS MAXIMUM SINGLE COMPONENT 4TH SECONDARY 113.00 AC VOLTS MINIMUM AND 195.00 AC VOLTS MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
WINDING OPERATING CURRENT | 10.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY 15.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY 30.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 4TH SECONDARY |
FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
WINDING FUNCTION AND QUANTITY | 1 PRIMARY AND 4 SECONDARY SINGLE COMPONENT |
INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO SINGLE PHASE AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
MOUNTING METHOD | FLANGE AND UNTHREADED HOLE SINGLE GROUP |
MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
MOUNTING HOLE DIAMETER | 0.165 INCHES MINIMUM AND 0.175 INCHES MAXIMUM SINGLE GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
INCLOSURE TYPE | FULLY INCLOSED |
BODY LENGTH | 2.820 INCHES MAXIMUM |
BODY HEIGHT | 1.160 INCHES MAXIMUM |
BODY WIDTH | 2.250 INCHES MAXIMUM |
RELIABILITY INDICATOR | NOT ESTABLISHED |
III TRANSFORMER WINDING CONNECTION TYPE | DELTA-WYE |
III MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
(NON-CORE DATA) CUBIC MEASURE | 7.4 CUBIC INCHES |
Restrictions/Controls & Freight Information | NSN 5950-00-450-3435
Category | Code | Description |
---|---|---|
Shelf-Life Code: | 0 | Nondeteriorative |
Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
Controlled Inventory Item Code: | U | UNCLASSIFIED |
Precious Metals Indicator Code: | U | Precious metal type is unknown |
Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Category | Code | Description |
---|---|---|
NMF Description | 063420 | TRANSFORMERS,NOI,OR TRANSFORMER PAR |
Less than car load rating | ||
Less than truck load rating | W | Rating Variable |
Water commodity Code | 595 | unknown |
Originating Activity Code | KE | Naval ICP Philadelphia, PA 19111 |
Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
Air Special Handling | Z | No special handling required. |
Special Handling Code | 9 | unknonwn |
HAZMAT | ||
Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5950-00-450-3435
Category | Code | Description |
---|---|---|
Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
Agency | DN | Department of the Navy |
Service Organization | N | U.S. Navy |
Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
Controlled Item Code | U | UNCLASSIFIED |
Shelf Life Code | 0 | Nondeteriorative |
Purchasing | QTY UOM |
1 EA : Each |