NSN 5985-01-478-3539 G7059395, G705939-5, 179.585-5

Product Details | FIXED ATTENUATOR


5985-01-478-3539 A device for reducing the strength of an alternating current signal by a fixed or predetermined amount, without causing appreciable signal distortion, by maintaining correct impedance match.

Part Alternates: G7059395, G705939-5, 179.585-5 , 1795855, 2082604208, 2082-6042-08 , 4 T 8 , 4T8, 6608.19.AA , 660819AA, 5985-01-478-3539, 01-478-3539, 5985014783539, 014783539

Electrical and Electronic Equipment Components | Antennas, Waveguides, and Related Equipment

Supply Group (FSG) NSN Assign. NIIN
59 08 SEP 2000 01-478-3539

Drawings & Photos | NSN 5985-01-478-3539



Demand History | NSN 5985-01-478-3539


Part Number Request Date QTY Origin
5985-01-478-3539 2017-02-02 43 DIBBS
5985-01-478-3539 2014-05-20 4 DIBBS
5985-01-478-3539 2014-02-25 2 DIBBS
5985-01-478-3539 2012-05-17 5 DIBBS
5985-01-478-3539 2010-07-30 2 DIBBS
5985-01-478-3539 2010-03-25 7 DIBBS

Cross Reference | NSN 5985-01-478-3539


Part Number Cage Code Manufacturer
179.585-5 C1798 AEROMARITIME SYSTEMBAU GMBH
2082-6042-08 3HT76 XMA CORPORATION DBA OMNI SPECTRA
2082-6042-08 96341 COBHAM ELECTRONIC SYSTEMS INC. DBA COBHAM DEFENSE ELECTRONICS
4 T 8 93459 AEROFLEX / WEINSCHEL, INC.
6608.19.AA C1375 HUBER + SUHNER GMBH
G705939-5 49956 RAYTHEON COMPANY DBA RAYTHEON
G705939-5 7Y193 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote



Comments | What our customers are saying...


Honeywell

Thank you very much for the excellent service and professional customer care.

Ernie G. Honeywell
Raytheon

The service was excellent. I can think of no improvements to date that you can make regarding internet sales.

John L. Raytheon
General Dynamics

The representative for WBParts was efficient & handled our request in a timely & professional manner.

Karen G. General Dynamics
US Airforce

Tried two other sources, neither of them responded, was all done online, never spoke to anyone.

Rex S. US Airforce
NASA

The response is quick and the price is often very good. We are completely satisfied.


NSNs for Compare ( up to 4 ): Add 5985-01-478-3539


Technical Data | NSN 5985-01-478-3539


Characteristic Specifications
APPLICATION DESIGN TRANSMISSION LINE
INPUT IMPEDANCE RATING IN OHMS 50.0
OUTPUT IMPEDANCE RATING IN OHMS 50.0
FREQUENCY RANGE 0.000 HERTZ MINIMUM AND 18.000 GIGAHERTZ MAXIMUM
VOLTAGE STANDING WAVE RATIO 1.15 AND 1.25 AND 1.35
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE 0.0 TO 4.0 GIGAHERTZ AND 4.0 TO 12.4 GIGAHERTZ AND 12.4 TO 18.0 GIGAHERTZ
RF SIGNAL ATTENUATION IN DECIBELS 8.0
ATTENUATION ACCURACY IN DECIBELS -0.50 TO 0.50
POWER RATING 2.0 WATTS AVERAGE AND 500.0 WATTS PEAK
BODY STYLE 1B ROUND, TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 0.860 INCHES NOMINAL
OVERALL DIAMETER 0.280 INCHES NOMINAL
BODY MATERIAL STEEL, CORROSION RESISTING
BODY SURFACE TREATMENT PASSIVATED
TERMINAL TYPE AND QUANTITY 2 CONNECTOR
COAXIAL CONNECTOR SERIES DESIGNATION SMA
MOUNTING METHOD CONNECTOR

Restrictions/Controls & Freight Information | NSN 5985-01-478-3539


Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 060535 AERIAL/ANTENNAS DIRECTIONAL
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 723 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5985-01-478-3539


Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item Code7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each

Looking to compare NSN's... try our NSN Compare Tool