NSN 6110-01-117-0889 IC5181D103A6XABX, MILDTL2212, MIL-DTL-2212

Product Details | MAGNETIC CONTACTOR


6110-01-117-0889 An item consisting of contacts, a magnetic core, and a coil with or without inclosure which is used to repeatedly establish and break a circuit. The item does not provide overload protection and is not used in line to control any other electrical controls. Excludes RELAY, ELECTROMAGNETIC and STARTER, MOTOR.l circuit. Exludes RELAY, ELECTRO-MAGNETIC and STARTER, MOTOR.

Part Alternates: IC5181D103A6XABX, MILDTL2212, MIL-DTL-2212, 6110-01-117-0889, 01-117-0889, 6110011170889, 011170889

Electric Wire, and Power and Distribution Equipment | Electrical Control Equipment

Supply Group (FSG) NSN Assign. NIIN
61 08 AUG 1981 01-117-0889

Demand History | NSN 6110-01-117-0889


Part Number Request Date QTY Origin
6110-01-117-0889 2015-05-18 2 DIBBS
6110-01-117-0889 2015-05-05 2 DIBBS
6110-01-117-0889 2015-04-02 1 DIBBS

Cross Reference | NSN 6110-01-117-0889


Part Number Cage Code Manufacturer
IC5181D103A6XABX 0C259 NETWORK SYSTEMS CORP
IC5181D103A6XABX 24374 BECHTEL TECHNICAL SERVICES INC MACHINERY APPARATUS OPN
MIL-DTL-2212 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY

Request a Quote



Comments | What our customers are saying...


Honeywell

Thank you very much for the excellent service and professional customer care.

Ernie G. Honeywell
Raytheon

The service was excellent. I can think of no improvements to date that you can make regarding internet sales.

John L. Raytheon
General Dynamics

The representative for WBParts was efficient & handled our request in a timely & professional manner.

Karen G. General Dynamics
US Airforce

Tried two other sources, neither of them responded, was all done online, never spoke to anyone.

Rex S. US Airforce
NASA

The response is quick and the price is often very good. We are completely satisfied.


NSNs for Compare ( up to 4 ): Add 6110-01-117-0889


Technical Data | NSN 6110-01-117-0889


Characteristic Specifications
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN DESIGNED PER NEMA STD
SIZE DESIGNATOR 3
OPERATING VOLTAGE CHARACTERISTIC FULL
AC VOLTAGE RATING 440.0 VOLTS NOMINAL
FREQUENCY RATING 60.0 HERTZ NOMINAL
PHASE THREE
AMP SIZE RATING 90.0
HORSEPOWER RATING 50.000
CONTROL TYPE LOCAL OR REMOTE
ACTUATION METHOD MAGNETIC
ACTUATOR VOLTAGE 440.0 AC
FREQUENCY IN HERTZ 60.0
CIRCUIT PROTECTION FUSE NOT PROVIDED
PERFORMANCE TYPE AUTOMATIC
DUTY CYCLE CONTINUOUS
AMBIENT TEMP 50.0 DEG CELSIUS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION ANY ACCEPTABLE
INCLOSURE FEATURE ANY ACCEPTABLE
OVERALL WIDTH 8.920 INCHES MINIMUM AND 9.040 INCHES MAXIMUM
OVERALL LENGTH 8.130 INCHES MINIMUM AND 8.250 INCHES MAXIMUM
OVERALL HEIGHT 7.820 INCHES MINIMUM AND 7.940 INCHES MAXIMUM
MOUNTING CONFIGURATION FOUR 3/8 IN. DIA MTG HOLES FOR 5/16 IN. DIA BOLTS ON 6-5/32 IN. BY 5-31/32 IN. MTG CTR
ACCESSORY INCLUDED
ACCESSORY LOCATION EXTERNAL AND INTERNAL
ACCESSORY CONTROLLING AGENCY GENERAL ELECTRIC CO
ACCESSORY IDENTIFYING NUMBER XABX CATALOG NO.
SPECIAL FEATURES SPECIAL REQUIREMENTS FOR NUCLEAR PROPULSION PLANT EQUIPMENT CONTAINED IN INDIVIDUAL REPAIR PARTS ORDERING DATA INSTRUMENTATION CONTROL NO. 4786-CGN36/37-0128,REV 1,LINE NO. 005

Restrictions/Controls & Freight Information | NSN 6110-01-117-0889


Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061300 CIRCUIT BREAKER/SWITCH NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 590 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 6110-01-117-0889


Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each

Call us today at (321) 473-6075 or Email us at sales@wbparts.com

Supply Chain Solutions Beyond Expectations. Check out the many ways our site can help you. Start Here