NSN 6625-00-120-0266 8020, 00-120-0266, 001200266

Product Details | PULSE GENERATOR


6625-00-120-0266 An electronic device which develops a discontinuous electrical potential with an abrupt rate of change of voltage which determines the harmonic content of the pulse train. The duration of a single pulse output is relatively short compared to the time of the recurrence cycle. See also GENERATOR, SINGLE PULSE; and GENERATOR, ELECTRONIC MARKER.20358950037Miscellaneous Communication Equipment61150041Generators and Generator Sets, Electrical66250070Electrical and Electronic Properties Measuring and Testing Instruments

Part Alternates: 8020, 6625-00-120-0266, 00-120-0266, 6625001200266, 001200266

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 04 JAN 1973 00-120-0266

Drawings & Photos | NSN 6625-00-120-0266



Demand History | NSN 6625-00-120-0266


Part Number Request Date QTY Origin
8020 2011-04-08 5 Taiwan
8020 2011-03-26 50 SA

Cross Reference | NSN 6625-00-120-0266


Part Number Cage Code Manufacturer
8020 23908 BNC CORP DBA BERKELEY NUCLEONICS

Request a Quote



Comments | What our customers are saying...


Honeywell

Thank you very much for the excellent service and professional customer care.

Ernie G. Honeywell
Raytheon

The service was excellent. I can think of no improvements to date that you can make regarding internet sales.

John L. Raytheon
General Dynamics

The representative for WBParts was efficient & handled our request in a timely & professional manner.

Karen G. General Dynamics
US Airforce

Tried two other sources, neither of them responded, was all done online, never spoke to anyone.

Rex S. US Airforce
NASA

The response is quick and the price is often very good. We are completely satisfied.


NSNs for Compare ( up to 4 ): Add 6625-00-120-0266


Technical Data | NSN 6625-00-120-0266


Characteristic Specifications
FREQUENCY PER CHANNEL 0.5 HERTZ MINIMUM 1ST OUTPUT CHANNEL 10.0 HERTZ MAXIMUM 1ST OUTPUT CHANNEL 3.0 KILOHERTZ MINIMUM 2ND OUTPUT CHANNEL 125.0 MEGAHERTZ MAXIMUM 2ND OUTPUT CHANNEL
FREQUENCY ADJUSTMENT TYPE CONTINUOUS
ATTENUATION IN DECIBELS NOT RATED
AVERAGE POWER RATING PER CHANNEL NOT RATED
SIGNAL VOLTAGE RATING PER CHANNEL NOT RATED
OVERALL GAIN NOT RATED
IMPEDANCE RATING PER CHANNEL 50.000 OHMS 1ST OUTPUT CHANNEL 50.000 OHMS 2ND OUTPUT CHANNEL
PULSE PEAK AMPLITUDE PER CHANNEL 800.000 MILLIVOLTS 1ST OUTPUT CHANNEL 800.000 MILLIVOLTS 2ND OUTPUT CHANNEL
PULSE DURATION PER CHANNEL 3.000 NANOSECONDS MINIMUM 1ST OUTPUT CHANNEL 100.000 MICROSECONDS MAXIMUM 1ST OUTPUT CHANNEL 3.000 NANOSECONDS MINIMUM 2ND OUTPUT CHANNEL 100.000 MICROSECONDS MAXIMUM 2ND OUTPUT CHANNEL
PULSE RISE TIME PER CHANNEL 1.000 NANOSECONDS NOMINAL 1ST OUTPUT CHANNEL 1.000 NANOSECONDS NOMINAL 2ND OUTPUT CHANNEL
PULSE DECAY TIME PER CHANNEL 1.300 NANOSECONDS NOMINAL 1ST OUTPUT CHANNEL 1.300 NANOSECONDS NOMINAL 2ND OUTPUT CHANNEL
SIGNAL DATA TYPE PER CHANNEL 1ST OUTPUT CHANNEL PULSE 2ND OUTPUT CHANNEL PULSE
MAXIMUM CONTINUOUS OPERATING TIME IN HOURS NOT RATED
AVERAGE LIFE MEASUREMENT NOT RATED
MAXIMUM OPERATING ALTITUDE RATING NOT RATED
OPERATING TEMP RANGE NOT RATED
VIBRATION RESISTANCE RANGE IN HERTZ NOT RATED
SHOCK RESISTANCE RATING IN GRAVITATIONAL UNITS NOT RATED
INCLOSURE TYPE ENCASED
MANUFACTURERS CODE 23908
DESIGN CONTROL REFERENCE 8020

Restrictions/Controls & Freight Information | NSN 6625-00-120-0266


Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information

Looking to compare NSN's... try our NSN Compare Tool

Supply Chain Solutions Beyond Expectations. Check out the many ways our site can help you. NSN Compare