NSN 6625-00-546-9321 AB-40, 103021RSSF7, 50103021RSSF2

Product Details | VOLTMETER


6625-00-546-9321 An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

Part Alternates: AB-40, 103021RSSF7, 50103021RSSF2, 50-103021RSSF2, AB40, 6625-00-546-9321, 00-546-9321, 6625005469321, 005469321

Instruments and Laboratory Equipment | Electrical and Electronic Properties Measuring and Testing Instruments

Supply Group (FSG) NSN Assign. NIIN
66 09 OCT 1974 00-546-9321

Drawings & Photos | NSN 6625-00-546-9321



Demand History | NSN 6625-00-546-9321


Part Number Request Date QTY Origin
AB40 2017-03-27 1 US
AB40 2010-04-03 1 Saudi Arabia
AB40 2007-12-04 1 US

Cross Reference | NSN 6625-00-546-9321


Part Number Cage Code Manufacturer
103021RSSF7 60336 YOKOGAWA CORPORATION OF AMERICA DIV FINANCE
50-103021RSSF2 03516 GENERAL ELECTRIC CO METER BUSINESS DEPT
AB-40 60336 YOKOGAWA CORPORATION OF AMERICA DIV FINANCE

Request a Quote



Comments | What our customers are saying...


Honeywell

Thank you very much for the excellent service and professional customer care.

Ernie G. Honeywell
Raytheon

The service was excellent. I can think of no improvements to date that you can make regarding internet sales.

John L. Raytheon
General Dynamics

The representative for WBParts was efficient & handled our request in a timely & professional manner.

Karen G. General Dynamics
US Airforce

Tried two other sources, neither of them responded, was all done online, never spoke to anyone.

Rex S. US Airforce
NASA

The response is quick and the price is often very good. We are completely satisfied.


NSNs for Compare ( up to 4 ): Add 6625-00-546-9321


Technical Data | NSN 6625-00-546-9321


Characteristic Specifications
INSTALLATION DESIGN PANEL
(NON-CORE DATA) PANEL FOR WHICH DESIGNED MAGNETIC
(NON-CORE DATA) CIRCUIT CONSTRUCTION TYPE NONELECTRONIC
INDICATOR TYPE DIAL W/POINTER
MEASUREMENT RANGE 0.0 TO 500.0 VOLTS, AC SINGLE INDICATOR SINGLE RANGE
ACCURACY IN PERCENT -1.0 TO 1.0 AT FULL SCALE SINGLE INDICATOR SINGLE RANGE
SCALE GRADUATION TYPE LINEAR SINGLE INDICATOR SINGLE RANGE
SCALE DIVISION QUANTITY 50 SINGLE INDICATOR SINGLE RANGE
POINTER COLOR BLACK SINGLE INDICATOR SINGLE RANGE
DIAL SCALE MARKING COLOR BLACK SINGLE INDICATOR SINGLE RANGE
BACKGROUND COLOR WHITE SINGLE INDICATOR SINGLE RANGE
MOVEMENT TYPE MOVING IRON VANE
MOVEMENT SUSPENSION METHOD TAUT BAND
CIRCUIT ATTACHMENT METHOD AND QUANTITY 2 THREADED STUD
SENSITIVITY RATING 250.0 VOLTS
CIRCUIT CURRENT FOR WHICH DESIGNED AC
STYLE DESIGNATOR C2 RECTANGULAR FLUSH MTG
METER BODY DIAMETER BEHIND MOUNTING FLANGE 3.970 INCHES NOMINAL
METER DEPTH BEHIND MOUNTING FLANGE 3.781 INCHES NOMINAL
OVERALL HEIGHT 4.328 INCHES NOMINAL
OVERALL LENGTH 4.202 INCHES NOMINAL
OVERALL WIDTH 4.328 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED STUD
MOUNTING STUD DIAMETER 0.312 INCHES NOMINAL
MOUNTING STUD LENGTH 0.625 INCHES NOMINAL
MOUNTING ARRANGEMENT STYLE E3 FOUR HOLE/STUD RECTANGULAR/SQUARE
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 3.375 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 3.375 INCHES NOMINAL
MATERIAL STEEL
SURFACE TREATMENT ENAMEL
NUCLEAR HARDNESS CRITICAL FEATURE NONHARDENED
ENVIRONMENTAL PROTECTION HUMIDITY RESISTANT AND SHOCK RESISTANT AND WATER RESISTANT
FURNISHED ITEMS AND QUANTITY NUT 6; WASHER 6
FEATURES PROVIDED ZERO ADJUSTER
III FSC APPLICATION DATA ELEC,ELECT. PROPERTIES MEASURING AND TEST INSTRUMENTS

Restrictions/Controls & Freight Information | NSN 6625-00-546-9321


Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:QStrategic List Item (SLI). Demilitarization not required. SLI are non-MLI(Munitions List Items) controlled by the U.S. Dept. of Commerce through the Export Administration Regulations (EAR) and indicated on the Commerce Control List (CCL). Each CCL entry is preceded by a four-digit Export Control Commerce Control List Item (CCLI) – MUT to the point of scrap required outside the United States. Inside the United States, MUT is required when the DEMIL integrity code (IC) is “3” and MUT is not required when the DEMIL IC is “6.”
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information

Looking to compare NSN's... try our NSN Compare Tool

Supply Chain Solutions Beyond Expectations. Check out the many ways our site can help you. NSN Compare