Product Details | TUBEAXIAL FAN

4140-01-117-1620 A nonpositive displacement mechanical device without guide vanes and having an axial fan impeller inclosed within a tubular housing. It is designed primarily for duct installation to move air or gas axially over a wide range of volumes at medium pressures.20316800000259000004140000000

Part Alternates: BC2206F221, BC2206F22-1, BC2206F222, BC2206F22-2, 6010655008, 6010655-008, 4140-01-117-1620, 01-117-1620, 4140011171620, 011171620

Refrigeration, Air Conditioning, and Air Circulating Equipment | Fans, Air Circulators, and Blower Equipment

Supply Group (FSG) NSN Assign. NIIN
41 09 AUG 1981 01-117-1620

Drawings & Photos | NSN 4140-01-117-1620


Cross Reference | NSN 4140-01-117-1620

Part Number Cage Code Manufacturer
6010655-008 12436 BAE SYSTEMS NATIONAL SECURITY SOLUTIONS INC.
BC2206F22-1 04320 CURTISS-WRIGHT CONTROLS INTEGRATED SENSING, INC.
BC2206F22-2 04320 CURTISS-WRIGHT CONTROLS INTEGRATED SENSING, INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4140-01-117-1620

Technical Data | NSN 4140-01-117-1620

Characteristic Specifications
STYLE DESIGNATOR 31 FIXED
LENGTH 1.500 INCHES NOMINAL
HOUSING INSIDE DIAMETER 4.125 INCHES NOMINAL
MATERIAL PLASTIC BLADE ZINC HOUSING
DRIVE TYPE DIRECT
ROTATION DIRECTION FOR WHICH DESIGNED CLOCKWISE
PRIME MOVER TYPE ELECTRIC MOTOR
SPEED ADJUSTMENTS SINGLE SPEED
PRIME MOVER DRIVE SHAFT BEARING TYPE BALL
INCLOSURE TYPE PARTIALLY INCLOSED
AMBIENT TEMP AT FULL RATED POWER NOT RATED
ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
OPERATING SPEED AT RATED CAPACITY IN RPM 5300.0
VOLTAGE IN VOLTS AND CURRENT TYPE 115.0 AC
PHASE SINGLE
FREQUENCY IN HERTZ 400.0
AIR FLOW RATE 185.0 CUBIC FEET PER MINUTE NOMINAL
STATIC PRESSURE AT SPECIFIED AIR FLOW RATE 0.0 INCHES OF WATER
FLOW DIRECTION OUTWARD
MOUNTING FACILITY TYPE AND QUANTITY 2 FLANGE AND 8 UNTHREADED HOLE

Restrictions/Controls & Freight Information | NSN 4140-01-117-1620

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061920 FANS ELEC NOI IN BARREL/BOX/CRATE
Less than car load rating
Less than truck load rating J 100.2
Water commodity Code 752 unknown
Originating Activity Code CX Defense Supply Center Richmond
Richmond, VA 23297-5000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable