Product Details | CENTRIFUGAL PUMP UNIT

4320-01-630-3625 An assembled unit consisting of a commonly mounted centrifugal pump(s), prime mover(s), and the necessary components to provide for a complete operation.

Part Alternates: 505325 , 4320-01-630-3625, 01-630-3625, 4320016303625, 016303625

Pumps and Compressors | Power and Hand Pumps

Supply Group (FSG) NSN Assign. NIIN
43 2014213 01-630-3625

Cross Reference | NSN 4320-01-630-3625

Part Number Cage Code Manufacturer
505325 04297 LITTLE GIANT PUMP CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4320-01-630-3625

Technical Data | NSN 4320-01-630-3625

Characteristic Specifications
MAXIMUM DISCHARGE FLOW RATE 20.0 GALLONS PER MINUTE
DISCHARGE PRESSURE 11.5 POUNDS PER SQUARE INCH GAGE
TOTAL HEAD 1200.0 FEET
SUCTION LIFT 25.0 FEET
MEDIA FOR WHICH DESIGNED LIQUID
PUMPING ELEMENT OPERATING POSITION VERTICAL
CENTRIFUGAL PUMP IMPELLER QUANTITY 1
VOLUME CONTROL TYPE SERVO MOTOR
CONTROL LOCATION CENTER
PUMP QUANTITY 1
INTAKE CONNECTION QUANTITY 1
DISCHARGE CONNECTION QUANTITY 1
DISCHARGE CONNECTION TYPE THREADED INTERNAL
DISCHARGE CONNECTION THREAD SIZE AND SERIES/TYPE DESIGNATOR 1.0 NPT
PRIME MOVER TYPE ELECTRIC MOTOR
PRIME MOVER QUANTITY 1
PRIME MOVER POWER RATING 16.7 HORSEPOWER
CURRENT TYPE AC
VOLTAGE IN VOLTS 230.0
INCLOSURE TYPE FULLY INCLOSED
MOUNTING TYPE FOOT
SPECIAL FEATURES SUBMERSIBLE PUMP, SERIES 5-MSPR, 1/6 HP, 230 VAC, 1-INCH FNPT DISCHARGE, 25-FOOT CORD
III PART NAME ASSIGNED BY CONTROLLING AGENCY SUPPLIED WITH 25-FOOT CORD; 1/6 HP OIL-FILLED MOTOR, 1-INCH FNPT DISCHARGE CONNECTION WITH GARDEN HOSE ADAPTER

Restrictions/Controls & Freight Information | NSN 4320-01-630-3625

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information