Product Details | SPACE HEATER

4520-00-409-9458 A device designed to burn various types of fuel within an inclosure which protects and confines the fire. It is used for the purpose of raising the temperature of the air in its immediate vicinity. The inclosure may be vented. Excludes HEATER, DUCT TYPE, PORTABLE and HEATER, SPACE, ELECTRIC.

Part Alternates: 012Q5168, 012Q5-168, 08168, 08-168, 4520-00-409-9458, 00-409-9458, 4520004099458, 004099458

Plumbing, Heating, and Waste Disposal Equipment | Space and Water Heating Equipment

Supply Group (FSG) NSN Assign. NIIN
45 00-409-9458

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4520-00-409-9458

Technical Data | NSN 4520-00-409-9458

Characteristic Specifications
HEAT DELIVERY RATE 134000.0 BRITISH THERMAL UNIT
CURRENT TYPE AC
VOLTAGE IN VOLTS 115.0
FREQUENCY IN HERTZ 60.0
PHASE SINGLE
CURRENT RATING IN AMPS ANY ACCEPTABLE
HEATING ELEMENT TYPE BURNER
HEAT MEDIUM TYPE AIR
FUEL FEED METHOD INTERNAL PUMP
FUEL TYPE DF-A ARCTIC DIESEL FUEL OIL
IGNITION METHOD ELECTRODE
MOUNTING TYPE FLOOR SURFACE, FREE STANDING, DUCTED
HEIGHT 57.000 INCHES NOMINAL
WIDTH 31.000 INCHES NOMINAL
DEPTH 28.500 INCHES NOMINAL
AIR CIRCULATION DEVICE SQUIRREL CAGE BLOWER
QUANTITY 1
SPEED ADJUSTMENTS THREE SPEED
MAXIMUM AIR FLOW RATE 1200.0 CUBIC FEET PER MINUTE
PRIME MOVER TYPE ELECTRIC MOTOR
CIRCULATED AIR TYPE COOLING OR HEATED
INCLOSURE MATERIAL STEEL
SURFACE TREATMENT ENAMEL
OPERATING CONTROL TYPE HAND SWITCH
FUEL CONSUMPTION RATE PER HOUR 1.2 GALLONS
SPECIAL FEATURES BAROMETER DRAFT REGULATOR INCL; 1/2 HP ELEC MOTOR; 20 FT OF WIRE FOR DUCTSTAT INCL; W/SPARE BURNER NOZZLE AND ELECTRODE ASSY
III FLUE CONNECTION LOCATION ON TOP 4.562 IN. CENTER FROM FRONT

Restrictions/Controls & Freight Information | NSN 4520-00-409-9458

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Category Code Description
No Freight Information