| HOSE OR TUBING SPEC/STD DATA |
MIL-H-27267 SIZE 4 STANDARD |
| INNER CONVEYING TUBE MATERIAL |
PLASTIC, POLYTETRAFLUOROETHYLENE |
| INSIDE SURFACE CONDITION |
SMOOTH |
| LAYER COMPOSITION AND LOCATION |
OUTER LAYER BRAIDED CORROSION RESISTANT STEEL WIRE |
| OUTER COVERING ENVIRONMENTAL PROTECTION |
ACID RESISTANT AND ALCOHOL RESISTANT AND ETHYLENE GLYCOL AND FUEL RESISTANT AND OIL RESISTANT AND SOLVENT RESISTANT |
| EXTERIOR COLOR |
ANY ACCEPTABLE |
| CROSS-SECTIONAL SHAPE STYLE |
1 ROUND |
| INSIDE DIAMETER |
0.188 INCHES NOMINAL |
| OUTSIDE DIAMETER |
0.312 INCHES NOMINAL |
| MEASURING METHOD AND LENGTH |
11.250 INCHES NOMINAL WORKING |
| MINIMUM INSIDE BENDING RADIUS |
2.000 INCHES |
| FIRST END CONNECTION TYPE |
THREADED INTERNAL TUBE |
| FIRST END STYLE DESIGNATOR |
C3 SWIVEL NUT FLARE |
| FIRST END SEAT ANGLE IN DEG |
37.0 |
| FIRST END CONNECTION DESIGN |
STRAIGHT |
| FIRST END SWIVEL ACTION CAPABILITY |
NOT INCLUDED |
| FIRST END FITTING/COMPONENT AND MATERIAL |
COMPLETE FITTING STEEL, CORROSION RESISTING |
| FIRST END FITTING/COMPONENT AND SURFACE TREATMENT |
COMPLETE FITTING PASSIVATED |
| FIRST END THREAD SERIES DESIGNATOR |
UNJF |
| FIRST END NOMINAL THREAD SIZE |
0.438 INCHES |
| FIRST END THREAD CLASS |
3B |
| FIRST END THREAD DIRECTION |
RIGHT-HAND |
| SECOND END RELATIONSHIP WITH FIRST END |
NOT IDENTICAL |
| SECOND END CONNECTION TYPE |
THREADED INTERNAL TUBE |
| SECOND END STYLE DESIGNATOR |
C3 SWIVEL NUT FLARE |
| SECOND END SEAT ANGLE IN DEG |
37.0 |
| SECOND END CONNECTION DESIGN |
ELBOW |
| SECOND END FLOW ANGLE IN DEG |
90.0 |
| SECOND END SWIVEL ACTION CAPABILITY |
NOT INCLUDED |
| SECOND END FITTING/COMPONENT AND MATERIAL |
COMPLETE FITTING STEEL, CORROSION RESISTING |
| SECOND END FITTING/COMPONENT AND SURFACE TREATMENT |
COMPLETE FITTING PASSIVATED |
| SECOND END THREAD SERIES DESIGNATOR |
UNJF |
| SECOND END NOMINAL THREAD SIZE |
0.438 INCHES |
| SECOND END THREAD CLASS |
3B |
| SECOND END THREAD DIRECTION |
RIGHT-HAND |
| TEMP RATING |
-65.0 DEG FAHRENHEIT AND 450.0 DEG FAHRENHEIT |
| MAXIMUM OPERATING PRESSURE |
1500.0 POUNDS PER SQUARE INCH |
| HYDROSTATIC TEST PRESSURE |
3000.0 POUNDS PER SQUARE INCH |
| BURST TEST PRESSURE |
12000.0 POUNDS PER SQUARE INCH |
| VACUUM IN TORR |
50.8 |
| FEATURES PROVIDED |
ELECTROSTATIC DISCHARGE CAPABILITY |
| SPECIFICATION/STANDARD DATA |
96906-MS8000 GOVERNMENT STANDARD |
| MANUFACTURERS CODE |
00624 |
| DESIGN CONTROL REFERENCE |
AE1002128E0112 |