NSN 4730-00-152-6073 K5145014, K-5145014, PC5145014
Product Details | MAGNETIC PIPE PLUG
4730-00-152-6073 A pipe fitting primarily designed for installation in a lubrication or hydraulic system. It has an integral magnet in the body and external pipe threads.
Part Alternates: K5145014, K-5145014, PC5145014, 5145014, 0190000151, 019-00001-51, 4730-00-152-6073, 00-152-6073, 4730001526073, 001526073
Pipe, Tubing, Hose, and Fittings | Hose, Pipe, Tube, Lubrication, and Railing Fittings
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 47 | 06 OCT 1971 | 00-152-6073 | 22340 ( PLUG, PIPE, MAGNETIC ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 4730-00-152-6073
Related Products | NSN 4730-00-152-6073
Technical Data | NSN 4730-00-152-6073
| Characteristic | Specifications |
|---|---|
| MATERIAL | STEEL OVERALL |
| STYLE DESIGNATOR | E5 PLUG, MAGNETIC |
| CONNECTION STYLE | J1 PLAIN |
| THREAD SERIES DESIGNATOR | NPT EXTERNAL |
| NOMINAL THREAD SIZE | 0.375 INCHES EXTERNAL |
| THREAD DIRECTION | RIGHT-HAND EXTERNAL |
| SPECIAL FEATURES | MACHINE WRAPPED W/TEFLON TAPE |
| III END ITEM IDENTIFICATION | ROAD GRADER,HUBER MODEL F1500M,K-C LIST |
Restrictions/Controls & Freight Information | NSN 4730-00-152-6073
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 040500 | CAP/PLUG (PROTECTOR) |
| Less than car load rating | ||
| Less than truck load rating | Q | 70.0 |
| Water commodity Code | 576 | unknown |
| Originating Activity Code | PA | Marine Corps Logistics Base Albany, GA 31704-1128 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | B | Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 4730-00-152-6073
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
| Combat Essentiality Code | 5 | Critical Repair Part to a Combat Essential End Item. Those parts or components whose failure in a combat essential end item will render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency. |
| Materiel Management Code | C | Construction MaterielDefense Supply Center Columbus (DSCC) |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Echelon Identification Code | B | Consumable Repair Parts |
| Source of Supply | S9C | Defense Supply Center Columbus Columbus, OH 43215 |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9C | Navy-owned stocks of defense construction material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | S9C | Defense Supply Center Columbus Columbus, OH 43215 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Y | TERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |