Product Details | GLOBE VALVE

4810-01-430-7261 A valve with one inlet and one outlet connection with outlet flow parallel to inlet flow. The flow is controlled by the action of a stem which lifts the disk perpendicularly off the center axis of its seat. The stem is at a 90 degree (1.5708 radians) angle to axis of flow. Excludes VALVE, STOP-CHECK; COCK, SHUTOFF, SCREW STEM; and VALVE, SOLENOID.20248100015Valves, Powered48200018Valves, Nonpowered

Part Alternates: 1001575D, 100-15-75D, 4810-01-430-7261, 01-430-7261, 4810014307261, 014307261

Valves | Valves, Powered

Supply Group (FSG) NSN Assign. NIIN
48 02 MAY 1996 01-430-7261

Drawings & Photos | NSN 4810-01-430-7261


Cross Reference | NSN 4810-01-430-7261

Part Number Cage Code Manufacturer
100-15-75D 86184 GRISWOLD INDUSTRIES, CO. DBA CLA-VAL CO

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4810-01-430-7261

Technical Data | NSN 4810-01-430-7261

Characteristic Specifications
MATERIAL BRONZE BODY BRONZE SEAT STEEL COMP 303 STEM
STYLE DESIGNATOR A1 STRAIGHT THRU
FLOW CONTROL DEVICE DIAPHRAGM
VALVE OPERATION METHOD HYDRAULIC
CONNECTION TYPE THREADED INTERNAL PIPE ALL ENDS
CONNECTION STYLE G9 PLAIN ALL ENDS
BONNET TYPE INSIDE SPRING
BONNET ATTACHMENT METHOD BOLTED
III END ITEM IDENTIFICATION ENGINE,AIRCRAFT, F101-GE-100 (B-1)

Restrictions/Controls & Freight Information | NSN 4810-01-430-7261

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 051080 FAUCETS,BIBCOCKS,GATES VALVES
Less than car load rating
Less than truck load rating W Rating Variable
Water commodity Code 594 unknown
Originating Activity Code AH Defense Supply Center Columbus
Columbus, OH 43215
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable