Product Details | CHECK VALVE

4820-01-436-1067 A valve permitting flow in one direction only. It does not have a stem, except when equipped with a lever and weight and has no pressure adjustment. It may be inline or cartridge (manifold) design.

Part Alternates: MS2889212AL, MS28892-12AL, GHN102853, GHN10285-3 , 4820-01-436-1067, 01-436-1067, 4820014361067, 014361067

Valves | Valves, Nonpowered

Supply Group (FSG) NSN Assign. NIIN
48 11 SEP 1996 01-436-1067

Drawings & Photos | NSN 4820-01-436-1067


Cross Reference | NSN 4820-01-436-1067

Part Number Cage Code Manufacturer
MS28892-12AL 96906 MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 4820-01-436-1067

Technical Data | NSN 4820-01-436-1067

Characteristic Specifications
MATERIAL ALUMINUM BODY STEEL FLOW CONTROL DEVICE
SURFACE TREATMENT ANODIZE
STYLE DESIGNATOR A6 STRAIGHT THRU
FLOW CONTROL DEVICE DISK
MEDIA FOR WHICH DESIGNED FUEL/OIL, HYDROCARBON SINGLE RESPONSE
MAXIMUM OPERATING PRESSURE 3000.0 POUNDS PER SQUARE INCH SINGLE RESPONSE
MAXIMUM OPERATING TEMP 275.0 DEG FAHRENHEIT SINGLE RESPONSE
VALVE OPERATION METHOD AUTOMATIC
CONNECTION TYPE THREADED EXTERNAL TUBE ALL ENDS
CONNECTION STYLE B45 FLARELESS ALL ENDS
SEAT ANGLE 12.0 DEGREES ALL ENDS
THREAD SERIES DESIGNATOR UN ALL ENDS
NOMINAL THREAD SIZE 1.062 INCHES 1ST END
THREAD QUANTITY PER INCH 12 ALL ENDS
THREAD CLASS 3A ALL ENDS
THREAD DIRECTION RIGHT-HAND ALL ENDS
MOUNTING POSITION HORIZONTAL OR VERTICAL
DISK LOADING METHOD SPRING
OPENING PRESSURE SETTING 6.0 POUNDS PER SQUARE INCH
MANUFACTURERS CODE 96906
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MS28892-12AL

Restrictions/Controls & Freight Information | NSN 4820-01-436-1067

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information