Product Details | BLIND RIVET

5320-01-406-7903 An item consisting of two or more of the following components: stem, rivet body, sleeve, expander, bolt, and collar. It is a headed fastening device with the shank designed to be expanded by means of a separate or integral stem or mandrel, or bolt and expander. It is designed to be installed or expanded from one side only. Excludes NUT, BLIND ASSEMBLY.

Part Alternates: C9512068, C9512-06-8, CR7650S0608, CR7650S-06-08, 5320-01-406-7903, 01-406-7903, 5320014067903, 014067903

Hardware and Abrasives | Rivets

Supply Group (FSG) NSN Assign. NIIN
53 12 JAN 1995 01-406-7903

Drawings & Photos | NSN 5320-01-406-7903


Demand History | NSN 5320-01-406-7903

Part Number Request Date QTY Origin
0SB100-EU06-8 2021-06-165 100 DIBBS
CR7650S-06-08 2021-06-165 100 DIBBS

Cross Reference | NSN 5320-01-406-7903

Part Number Cage Code Manufacturer
C9512-06-8 81755 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN AERONAUTICS
CR7650S-06-08 11815 SPS TECHNOLOGIES, LLC DBA CHERRY AEROSPACE DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5320-01-406-7903

Technical Data | NSN 5320-01-406-7903

Characteristic Specifications
MATERIAL IRON ALLOY 660 OR NICKEL ALLOY K-500 LOCKING RING NICKEL ALLOY K-500 OR NICKEL ALLOY 502 SLEEVE IRON ALLOY 660 STEM
SURFACE TREATMENT CADMIUM AND CHROMATE SLEEVE PASSIVATE STEM
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION QQ-P-419,TYPE 2,CLASS 3 FED SPEC ALL TREATMENT RESPONSES SLEEVE QQ-P-35 FED SPEC SINGLE TREATMENT RESPONSE STEM
MINIMUM TENSILE STRENGTH 1500 POUNDS PER SQUARE INCH
SHANK STYLE D32 SELF-PLUGGING MECHANICALLY LOCKED STEM
FASTENER LENGTH 0.600 INCHES NOMINAL
GRIP LENGTH 0.470 INCHES MINIMUM AND 0.530 INCHES MAXIMUM

Restrictions/Controls & Freight Information | NSN 5320-01-406-7903

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information