Product Details | BLIND RIVET

5320-01-578-1828 An item consisting of two or more of the following components: stem, rivet body, sleeve, expander, bolt, and collar. It is a headed fastening device with the shank designed to be expanded by means of a separate or integral stem or mandrel, or bolt and expander. It is designed to be installed or expanded from one side only. Excludes NUT, BLIND ASSEMBLY.

Part Alternates: NAS1398D4A9, 5320-01-578-1828, 01-578-1828, 5320015781828, 015781828

Hardware and Abrasives | Rivets

Supply Group (FSG) NSN Assign. NIIN
53 29 SEP 2009 01-578-1828

Cross Reference | NSN 5320-01-578-1828

Part Number Cage Code Manufacturer
NAS1398D4A9 80205 NATIONAL AEROSPACE STANDARDS COMMITTEE AEROSPACE INDUSTRIES

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5320-01-578-1828

Technical Data | NSN 5320-01-578-1828

Characteristic Specifications
MATERIAL ALUMINUM ALLOY 2017 LOCKING RING
HEAD MAJOR DIAMETER 0.238 INCHES MINIMUM AND 0.262 INCHES MAXIMUM
GRIP LENGTH 0.188 INCHES MINIMUM AND 0.250 INCHES MAXIMUM
HEAD HEIGHT 0.054 INCHES MINIMUM AND 0.064 INCHES MAXIMUM
SURFACE TREATMENT ANODIZE SLEEVE OR CHROMATE SLEEVE
HEAD STYLE UNIVERSAL
SHANK DIAMETER 0.124 INCHES MINIMUM AND 0.128 INCHES MAXIMUM
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION MIL-A-8625 MIL SPEC 1ST TREATMENT RESPONSE SLEEVE OR MIL-C-5541 MIL SPEC 2ND TREATMENT RESPONSE SLEEVE
SHANK STYLE SELF-PLUGGING MECHANICALLY LOCKED STEM
SURFACE TREATMENT DOCUMENT AND CLASSIFICATION MIL-A-8625 MIL SPEC 1ST TREATMENT RESPONSE STEM OR MIL-C-5541 MIL SPEC 2ND TREATMENT RESPONSE STEM
MATERIAL DOCUMENT AND CLASSIFICATION QQ-A-430 FED SPEC SINGLE MATERIAL RESPONSE LOCKING RING
SURFACE TREATMENT ANODIZE STEM OR CHROMATE STEM

Restrictions/Controls & Freight Information | NSN 5320-01-578-1828

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information