Product Details | GENERAL PURPOSE RESILIENT MOUNT

5340-00-597-6325 An item made of material having elastic properties. It may have rigid mounting facilities such as a flange(s), sleeve(s), stud(s) or the like. It is designed to isolate or dampen shock and/or vibration of a continuous or intermittent origin and serve as a support for an item to be isolated. Excludes MOUNT, RESILIENT, WEAPON SYSTEM; SPRING (as modified); BUMPER, NONMETALLIC; BUMPER, RUBBER; BUSHING, NONMETALLIC; hydraulic and pneumatic shock absorbers, dashpots, grommets and shock pads.

Part Alternates: A301, 5340-00-597-6325, 00-597-6325, 5340005976325, 005976325

Hardware and Abrasives | Hardware, Commercial

Supply Group (FSG) NSN Assign. NIIN
53 01 JAN 1963 00-597-6325

Cross Reference | NSN 5340-00-597-6325

Part Number Cage Code Manufacturer
A301 61463 CHEMTURA CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5340-00-597-6325

Technical Data | NSN 5340-00-597-6325

Characteristic Specifications
RESILIENT MEMBER MATERIAL RUBBER
NONMETALLIC HARDNESS RATING NOT RATED
RIGID MEMBER MATERIAL AND LOCATION STEEL OVERALL
STYLE DESIGNATOR C1 ROUND W/FLANGE THREADED STUD
THREAD SIZE 8-32 NC
MAJOR OUTSIDE DIAMETER 0.563 INCHES NOMINAL
STUD LENGTH 0.375 INCHES NOMINAL
DISTANCE FROM FLANGE TO END 0.500 INCHES NOMINAL
STATIC LOAD RATING AT SPECIFIED DEFLECTION 5 LB LOAD RATING AT 0.400 IN. DEFLECTION
LOAD/FREQUENCY RANGE NOT SPECIFIED
MAXIMUM LOAD RATING NOT RATED

Restrictions/Controls & Freight Information | NSN 5340-00-597-6325

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information