Product Details | THREADED HINGED STANDOFF

5340-01-518-1628 A standoff, internally and/or externally, threaded on both ends with a hinge or pivot point to allow for independent movement of the ends.

Part Alternates: NAS1831C5D17, 5340-01-518-1628, 01-518-1628, 5340015181628, 015181628

Hardware and Abrasives | Hardware, Commercial

Supply Group (FSG) NSN Assign. NIIN
53 03 MAR 2004 01-518-1628

Drawings & Photos | NSN 5340-01-518-1628


Cross Reference | NSN 5340-01-518-1628

Part Number Cage Code Manufacturer
NAS1831C5D17 80205 NATIONAL AEROSPACE STANDARDS COMMITTEE AEROSPACE INDUSTRIES

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5340-01-518-1628

Technical Data | NSN 5340-01-518-1628

Characteristic Specifications
MATERIAL STEEL OVERALL
SURFACE TREATMENT CADMIUM OVERALL
CROSS-SECTIONAL SHAPE OCTAGON
WIDTH ACROSS FLATS 0.313 INCHES NOMINAL
STYLE DESIGNATOR 8 LEFT INTERNAL AND RIGHT INTERNAL THREADS
LENGTH 1.063 INCHES NOMINAL
THREAD SERIES DESIGNATOR UNC LEFT INTERNAL UNC RIGHT INTERNAL
NOMINAL THREAD SIZE 0.164 INCHES LEFT INTERNAL 0.164 INCHES RIGHT INTERNAL
THREAD QUANTITY PER INCH 32 LEFT INTERNAL
THREAD CLASS 2B LEFT INTERNAL 2B RIGHT INTERNAL
THREAD DIRECTION RIGHT-HAND LEFT INTERNAL RIGHT-HAND RIGHT INTERNAL
THREAD LENGTH 1.063 INCHES NOMINAL LEFT INTERNAL 1.063 INCHES NOMINAL RIGHT INTERNAL

Restrictions/Controls & Freight Information | NSN 5340-01-518-1628

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information