NSN 5410-01-039-9977 LOC-ARCH P-3, LOCARCHP3, 01-039-9977
Product Details | PANELIZED PREFABRICATED BUILDING
5410-01-039-9977 A structure constructed of metal and/or wood, prefabricated into assembled panels of specified dimensions. Designed for quick erection and dismantling, and adapted for various uses. Excludes SHELTER-CONTAINER, EXPANDABLE; and SHELTER, EXPANDABLE.
Part Alternates: LOC-ARCH P-3, LOCARCHP3, 5410-01-039-9977, 01-039-9977, 5410010399977, 010399977
Prefabricated Structures and Scaffolding | Prefabricated and Portable Buildings
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 54 | 29 APR 1977 | 01-039-9977 | 02395 ( BUILDING, PREFABRICATED, PANELIZED ) |
Cross Reference | NSN 5410-01-039-9977
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| LOC-ARCH P-3 | 98897 | LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN AERONAUTICS |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5410-01-039-9977
Related Products | NSN 5410-01-039-9977
Technical Data | NSN 5410-01-039-9977
| Characteristic | Specifications |
|---|---|
| GENERAL CHARACTERISTICS ITEM DESCRIPTION | HANGER AIRCRAFT MAINTENANCE LOC-ARCH P-3,138 FT WIDE,128 FT LONG,45 FT HIGH,ARCH ERECTION TOWERS,FIBERGLASS MOLDED STRUCTURAL ARCH BEAMS WITH BAYONET FITTINGS AND PIN CONNECTIONS,GROUND RAILS,FIBERGLASS MOLDED PANELS 4 FT BY 8 FT,CABLE CURTAIN END WALLS WITH DOOR EACH END,ROLLER ASSEMBLY FOR PANEL ERECTION PLUS OTHER MINOR ASSEMBILIES,80 KNOT WIND LOAD |
Restrictions/Controls & Freight Information | NSN 5410-01-039-9977
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 000000 | NO NMFC FREIGHT DESCRIPTION |
| Less than car load rating | F | 150 |
| Less than truck load rating | Z | No Rating |
| Water commodity Code | 749 | unknown |
| Originating Activity Code | JS | Naval ICP Mechanicsburg, PA 17055-0788 |
| Air Dimension Code | Z | Shipment is not a consolidation, but does exceed 72 inches in one or more dimensions. |
| Air Commodity | B | Construction materials: Includes paint and related materials, prefabricated building, wood products, metal and composition materials and their products, commercial hardware and miscellaneous items, cement, asphalt, building maintenance materials. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5410-01-039-9977
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 2C | Major construction and civil engineering equipment Civil Engineer Support Office 2D |
| Issue Repair, or Requisition | AH | Submit/refer requisitions to CESO (Civil Engineer Support Office) CBC Port Hueneme. |
| Special Material Content | 9 | Non-Hazardous or Non-Sensitive Item, does not require hazardous or special handling, packaging or precautions |
| Source of Supply | R41 | Naval Facilities Expenditionary Logistics Center Code N42 Bldg 1000 23rd Ave Port Hueneme, CA 93043 |
| Agency | DN | Department of the Navy |
| Service Organization | L | Lead Service - 22 (Repairable) |
| Reparability | V | 2C Cog CEEI Material (major end item) |
| Acquisition Advice Codes | A | SERVICE/AGENCY-REGULATED (Service/Agency use only.) # Issue, transfer or shipment is controlled by authorities above the ICP level to assure proper and equitable distribution. 1. The use or stockage of the item requires release authority based on prior or concurrent justification. 2. Requisitions will be submitted in accordance with Agency/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |