Product Details | SONAR TRANSDUCER

5845-01-537-4495 A device specifically designed to be used underwater to convert electrical energy into underwater sound energy and underwater sound energy into electrical energy. For items designed to convert underwater sound energy into electrical energy only, see HYDROPHONE, SONAR. For items designed to convert electrical energy into underwater sound energy only, see PROJECTOR, SONAR.

Part Alternates: HSA004816 , 512101, 51210-1, 5845-01-537-4495, 01-537-4495, 5845015374495, 015374495

Communication, Detection, and Coherent Radiation Equipment | Underwater Sound Equipment

Supply Group (FSG) NSN Assign. NIIN
58 08 FEB 2006 01-537-4495

Demand History | NSN 5845-01-537-4495

Part Number Request Date QTY Origin
512101 2018-09-250 2 US

Cross Reference | NSN 5845-01-537-4495

Part Number Cage Code Manufacturer
51210-1 24338 EDO WESTERN CORPORATION DBA EDO ELECTRO CERAMIC PRODUCTS
51210-1 Z0GY5 BAE SYSTEMS AUSTRALIA PTY LTD
HSA004816 Z0GY5 BAE SYSTEMS AUSTRALIA PTY LTD

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5845-01-537-4495

Technical Data | NSN 5845-01-537-4495

Characteristic Specifications
OVERALL DIAMETER 5.610 INCHES NOMINAL
OVERALL WIDTH 15.240 INCHES NOMINAL
OVERALL HEIGHT 6.700 INCHES NOMINAL
SPECIAL FEATURES 59.5 POUNDS WEIGHT IN AIR;40.3 POUNDS WEIGHT IN SALT WATER;PHASED ARRAY;2 ELEMENT TRANSDUCER,4 BEAMS,EACH BEAM 3 DEGREE NOMINAL WIDTH;60 DEGREES NOMINAL DEPRESSION ANGLE;MACHINED STAINLESS STEEL BODY
III END ITEM IDENTIFICATION DOPPLER VELOCITY LOG,MODEL 3060

Restrictions/Controls & Freight Information | NSN 5845-01-537-4495

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information