NSN 5895-01-498-5233 CTL92, CTL-92, 6226523205
Product Details | CONTROL-INDICATOR
5895-01-498-5233 A component which performs the dual function of presenting visual information from other sources such as navigation, radar and the like and regulating the mode of operation of those sources. This item is essential to the end use or operation of the other sources. See also CONTROL-MONITOR.20258950037Miscellaneous Communication Equipment66050024Navigational Instruments
Part Alternates: CTL92, CTL-92, 6226523205, 622-6523-205, 5895-01-498-5233, 01-498-5233, 5895014985233, 014985233
Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 58 | 29 JUN 2002 | 01-498-5233 | 00908 ( CONTROL-INDICATOR ) |
Demand History | NSN 5895-01-498-5233
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 6226523205 | 2011-01-24 | 1 | US |
| CTL92 | 2007-01-31 | 1 | UM |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5895-01-498-5233
Related Products | NSN 5895-01-498-5233
Technical Data | NSN 5895-01-498-5233
| Characteristic | Specifications |
|---|---|
| MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 AC AND 28.0 DC |
| MAXIMUM WATTAGE RATING IN WATTS | 7.0 |
| MAXIMUM OVERALL LENGTH | 190.9 MILLIMETERS |
| MAXIMUM OVERALL WIDTH | 60.32 MILLIMETERS |
| MAXIMUM OVERALL HEIGHT | 66.68 MILLIMETERS |
| OPERATING TEMP RANGE | -30.0 TO 70.0 DEG CELSIUS |
| SPECIAL FEATURES | PANEL MOUNTED, FRONT OR REAR; MATTING CONNECTOR CANNON MS3126F20-41SY; ALTITUDE 10 700 M MAX; COOLING CONVECTION; RELATIVE HUMIDITY 95 PCT AT P50 DEG FOR 10 DAYS; SHOCK 6 G OPERATIONAL, 13 G CRASH SAFETY; LIGHTING VOLTAGE 5V AC/DC; PANEL COLOR GRAY; DISPLAY TYPE GAS DISCHARGE; BRIGHTNESS CONTROL AUTOMATIC OR BY EXTERNAL CONTROL |
| III STORAGE TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
| III UNPACKAGED UNIT WEIGHT | 0.54 KILOGRAMS |
| III END ITEM IDENTIFICATION | TCAS-94 TRAFFIC ALERT AND COLLISION AVOIDANCE SYSTEM |
| III PART NAME ASSIGNED BY CONTROLLING AGENCY | TRANSPONDER CONTROL |
Restrictions/Controls & Freight Information | NSN 5895-01-498-5233
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | B | Munitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.) |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| No Freight Information | ||