Product Details | TACTICAL COMMAND SYSTEM

5895-01-540-7305 An integrated system of computer hardware, firmware and software used by trained operators and tactical decision makers to process and disseminate tactical data. It is specifically designed for mobile Command, Control and Communication and Intelligence(C3)functions to support mission assessment, planning execution with tactical displays, integrated information management systems, tactical communication decision and planning aids. Can be used with Tactical Airspace Integration System in A2C2, Army Airspace Command and Control planning and execution as part of the Tactical Command Center Architecture. Can also serve as an Airspace Information Center managing to perplanned comprehensive enroute airway structure and disseminating critical flight data affecting operations within Army airspace.

Part Alternates: ALH102358, ALH-102358, ALH102358001, ALH-102358-001, AN/GSQ-273, ANGSQ273, 5895-01-540-7305, 01-540-7305, 5895015407305, 015407305

Communication, Detection, and Coherent Radiation Equipment | Miscellaneous Communication Equipment

Supply Group (FSG) NSN Assign. NIIN
58 31 MAY 2006 01-540-7305

Cross Reference | NSN 5895-01-540-7305

Part Number Cage Code Manufacturer
ALH-102358 318U8 NORTHROP GRUMMAN SPACE & MISSION SYSTEMS CORP.
ALH-102358-001 318U8 NORTHROP GRUMMAN SPACE & MISSION SYSTEMS CORP.
AN/GSQ-273 80058 JOINT ELECTRONICS TYPE DESIGNATION SYSTEM

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5895-01-540-7305

Technical Data | NSN 5895-01-540-7305

Characteristic Specifications
END ITEM IDENTIFICATION SICPS BASE LAN
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM NAME COMMAND SYSTEM, TACTICAL
JOINT ELECTRONICS TYPE DESIGNATION SYSTEM ITEM TYPE NUMBER AN/GSQ-273
SPECIAL FEATURES INTEGRATED SWITCH, ROUTER, FIREWALL, MEDIA CONVERTER, POWER STRIP, AND PATCH PANELS FOR LAN OPERATION. 19-INCH RACK-MOUNT TRANSIT CASE. MIL-STD-810 COMPLIANT. OPERATING POWER REQUIREMENTS, 110-120 VAC FROM COMMERCIAL OR TACTICAL POWER, MINIMUM 1KW SOURCE.

Restrictions/Controls & Freight Information | NSN 5895-01-540-7305

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:BMunitions List Item - Mutilation (MUT) to the point of scrap required. (Formerly: Demilitarization not required. Trade Security Controls (TSCs) required at disposition.)
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information

Management | NSN 5895-01-540-7305

Category Code Description
Materiel Category and Inventory ManagerG Communications and Electronics Equipment, Electronics Materiel
Appropriation and Budget ActivityP Communications and Electronics Equipment (except Safeguard)
Management Inventory Segment4 PROVISIONING ITEMS (Exclusive of Insurance Items). This code will identify new items introduced through the provisioning process for system stock which would normally be categorized as either nonreparable or reparable but for which sufficient experience has been obtained to manage on the basis of normal demand forecasts.
Specific Group/Generic Code7 Communications Systems Equipment
Weapons Systems/End Item or Homogeneous Group72Tactical Operations Center (TOC)
Accounting Requirements CodeN Nonexpendable item. An item of Army property coded with an ARC of?N?in the AMDF. Nonexpendable items require property book accountability after issue from the stock record account. Commercial and fabricated items similar to items coded ?N? in the AMDF are considered nonexpendable items.
Source of SupplyB16US Army Communications-Electronics
Command and Fort Monmouth
Fort Monmouth, NJ 07703-5016
AgencyDADepartment of the Army
Service OrganizationLLead Service - 22 (Repairable)
Acquisition Advice CodesVTERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each