Product Details | THERMAL RESISTOR

5905-00-132-2430 A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.

Part Alternates: KA29J1, 5905-00-132-2430, 00-132-2430, 5905001322430, 001322430

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 13 DEC 1968 00-132-2430

Cross Reference | NSN 5905-00-132-2430

Part Number Cage Code Manufacturer
KA29J1 02606 BAXTER HEALTHCARE CORPORATION DBA BAXTER BIOTECH DIV TRANSFUSION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-00-132-2430

Technical Data | NSN 5905-00-132-2430

Characteristic Specifications
ZERO POWER RESISTANCE 900.000 OHMS
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP -10.0 TO 10.0
AMBIENT TEMP AT FULL RATED POWER 25.0 DEG CELSIUS
MAXIMUM OPERATING TEMP 300.0 DEG CELSIUS
THERMAL TIME CONSTANT IN SECONDS 20.0
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS 6.0
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS -4.40
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -60.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT -30.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT 30.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT 60.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT 90.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT 120.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT 150.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT 200.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT 300.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP 126.4 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT 15.9 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT 2.9 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT 725.1 OHMS 4TH RESISTANCE-TEMPERATURE POINT 223.9 OHMS 5TH RESISTANCE-TEMPERATURE POINT 82.4 OHMS 6TH RESISTANCE-TEMPERATURE POINT 35.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT 16.7 OHMS 8TH RESISTANCE-TEMPERATURE POINT 5.9 OHMS 9TH RESISTANCE-TEMPERATURE POINT 1.25 OHMS 10TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -16.6 TO 16.6 1ST RESISTANCE-TEMPERATURE POINT -13.8 TO 13.8 2ND RESISTANCE-TEMPERATURE POINT -11.5 TO 11.5 3RD RESISTANCE-TEMPERATURE POINT -10.4 TO 10.4 4TH RESISTANCE-TEMPERATURE POINT -12.0 TO 12.0 5TH RESISTANCE-TEMPERATURE POINT -13.4 TO 13.4 6TH RESISTANCE-TEMPERATURE POINT -14.6 TO 14.6 7TH

Restrictions/Controls & Freight Information | NSN 5905-00-132-2430

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable