Product Details | FILM FIXED RESISTOR NETWORK

5905-00-264-9945 An arrangement of multiple fixed resistive elements or discrete resistors permanently encased, encapsulated, or potted together, to form an inseparable unit. The resistive elements, consisting of a thin layer of conductive material deposited on or fused to an insulating base, usually are electrically connected to each other and may be arranged in any circuit configuration. Excludes RESISTOR, FIXED (as modified); RESISTOR ASSEMBLY; RESISTOR NETWORK, FIXED-VARIABLE; and RESISTOR SET, MATCHED.

Part Alternates: 139D640PC8, 2000PT301, 998127PC8, 5905-00-264-9945, 00-264-9945, 5905002649945, 002649945

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-264-9945

Drawings & Photos | NSN 5905-00-264-9945


Cross Reference | NSN 5905-00-264-9945

Part Number Cage Code Manufacturer
139D640PC8 24446 GENERAL ELECTRIC CO
2000PT301 58880 MEGGITT (NEW HAMPSHIRE), INC
998127PC8 10001 NAVAIR AND NAVSEA MANAGED ORIGINAL DESIGN ACTIVITY DWG NOT

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-00-264-9945

Technical Data | NSN 5905-00-264-9945

Characteristic Specifications
ELECTRICAL RESISTANCE 78.900 KILOHMS 133.440 KILOHMS
IDENTICAL VALUE RESISTOR QUANTITY 1 LOWEST RESISTANCE VALUE 1 HIGHEST RESISTANCE VALUE
RESISTANCE TOLERANCE IN PERCENT -0.100 TO 0.100
POWER DISSIPATION RATING IN WATTS 2.000 TOTAL NETWORK
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 70.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 95.0
SCHEMATIC DIAGRAM DESIGNATOR 1 ISOLATED ARRAY
INCLOSURE METHOD HERMETICALLY SEALED
STYLE DESIGNATOR 130 TERMINALS ONE END
BODY LENGTH 1.553 INCHES MINIMUM AND 1.573 INCHES MAXIMUM
BODY WIDTH 1.490 INCHES MINIMUM AND 1.510 INCHES MAXIMUM
BODY HEIGHT 0.865 INCHES MINIMUM AND 0.885 INCHES MAXIMUM
TERMINAL TYPE TURRET
TERMINAL QUANTITY 2
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH 0.521 INCHES MINIMUM AND 0.541 INCHES MAXIMUM
(NON-CORE DATA) CUBIC MEASURE 2.102 CUBIC INCHES

Restrictions/Controls & Freight Information | NSN 5905-00-264-9945

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5905-00-264-9945

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each