Product Details | INDUCTIVE WIRE WOUND FIXED RESISTOR

5905-00-901-8381 INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.

Part Alternates: SA5050000HMSP0RM5PCT, 1290293, 12902-93, 243E5025, 5905-00-901-8381, 00-901-8381, 5905009018381, 009018381

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 00-901-8381

Drawings & Photos | NSN 5905-00-901-8381


Cross Reference | NSN 5905-00-901-8381

Part Number Cage Code Manufacturer
12902-93 50027 FLIGHTLINE ELECTRONICS, INC. DBA ULTRA ELEC FLIGHTLINE SYSTEMS
225S5K000J 44655 HEICO OHMITE, L.L.C. DBA OHMITE MANUFACTURING
243E5025 80183 SPRAGUE PRODUCTS CO
25J5KO 44655 HEICO OHMITE, L.L.C. DBA OHMITE MANUFACTURING
SA5050000HMSP0RM5PCT 53655 AVOX SYSTEMS INC.

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-00-901-8381

Technical Data | NSN 5905-00-901-8381

Characteristic Specifications
ELECTRICAL RESISTANCE 5.000 KILOHMS
RESISTANCE TOLERANCE IN PERCENT -5.000 TO 5.000
POWER DISSIPATION RATING IN WATTS 5.000 FREE AIR
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER 25.0
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER 275.0
TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS -260.0 TO 260.0
TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS -55.0 TO 275.0
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 14 AXIAL TERMINAL EACH END
BODY DIAMETER 0.344 INCHES NOMINAL
BODY LENGTH 1.000 INCHES NOMINAL
TERMINAL TYPE WIRE LEAD
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT 78626-12902 DRAWING
MANUFACTURERS CODE 50027
MFR SOURCE CONTROLLING REFERENCE 12902-93

Restrictions/Controls & Freight Information | NSN 5905-00-901-8381

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Category Code Description
No Freight Information