NSN 5905-01-026-6016 LO2221, 109771, 310681
Product Details | FILM FIXED RESISTOR NETWORK
5905-01-026-6016 An arrangement of multiple fixed resistive elements or discrete resistors permanently encased, encapsulated, or potted together, to form an inseparable unit. The resistive elements, consisting of a thin layer of conductive material deposited on or fused to an insulating base, usually are electrically connected to each other and may be arranged in any circuit configuration. Excludes RESISTOR, FIXED (as modified); RESISTOR ASSEMBLY; RESISTOR NETWORK, FIXED-VARIABLE; and RESISTOR SET, MATCHED.
Part Alternates: LO2221, 109771, 310681, 5905-01-026-6016, 01-026-6016, 5905010266016, 010266016
Electrical and Electronic Equipment Components | Resistors
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 28 AUG 1976 | 01-026-6016 | 32068 ( RESISTOR NETWORK, FIXED, FILM ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5905-01-026-6016
Related Products | NSN 5905-01-026-6016
Technical Data | NSN 5905-01-026-6016
| Characteristic | Specifications |
|---|---|
| ELECTRICAL RESISTANCE | 5.000 KILOHMS 10.000 KILOHMS 9.998 KILOHMS |
| IDENTICAL VALUE RESISTOR QUANTITY | 12 LOWEST RESISTANCE VALUE 1 INTERMEDIATE RESISTANCE VALUE 12 HIGHEST RESISTANCE VALUE |
| RESISTANCE TOLERANCE IN PERCENT | -0.005 TO 0.005 |
| POWER DISSIPATION RATING IN WATTS | NOT RATED |
| AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | NOT RATED |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | NOT RATED |
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -3.0 TO 3.0 |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 125.0 |
| SCHEMATIC DIAGRAM DESIGNATOR | 2 LADDER NETWORK |
| INCLOSURE METHOD | ENCAPSULATED |
| STYLE DESIGNATOR | 218 SINGLE INLINE |
| BODY LENGTH | 2.300 INCHES MAXIMUM |
| BODY WIDTH | 0.375 INCHES MAXIMUM |
| BODY HEIGHT | 1.250 INCHES MAXIMUM |
| TERMINAL TYPE | WIRE LEAD |
| TERMINAL QUANTITY | 15 |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TERMINAL LENGTH | 1.000 INCHES MINIMUM |
| SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DESC PRODUCTION STANDARD NO. L02221; FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY |
| CRITICALITY CODE JUSTIFICATION | FEAT |
Restrictions/Controls & Freight Information | NSN 5905-01-026-6016
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Electro-static Discharge Susceptible: | B | ESD sensitivity |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | Y | The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 062960 | REOSTATS/PARTS NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | 3 | Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices). |
Management | NSN 5905-01-026-6016
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | J | NOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |