Product Details | FILM FIXED RESISTOR NETWORK

5905-01-077-2554 An arrangement of multiple fixed resistive elements or discrete resistors permanently encased, encapsulated, or potted together, to form an inseparable unit. The resistive elements, consisting of a thin layer of conductive material deposited on or fused to an insulating base, usually are electrically connected to each other and may be arranged in any circuit configuration. Excludes RESISTOR, FIXED (as modified); RESISTOR ASSEMBLY; RESISTOR NETWORK, FIXED-VARIABLE; and RESISTOR SET, MATCHED.

Part Alternates: 58273, 582-73, 60919751, 6091975-1, 5905-01-077-2554, 01-077-2554, 5905010772554, 010772554

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 20 MAY 1979 01-077-2554

Drawings & Photos | NSN 5905-01-077-2554


Cross Reference | NSN 5905-01-077-2554

Part Number Cage Code Manufacturer
582-73 11236 CTS CORP BERNE DIV THICK FILM PRODUCTS GROUP
6091975-1 03640 LOCKHEED MARTIN CORPORATION DBA LOCKHEED MARTIN

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-077-2554

Technical Data | NSN 5905-01-077-2554

Characteristic Specifications
ELECTRICAL RESISTANCE 20.000 OHMS 5.620 KILOHMS 365.000 OHMS 620.000 OHMS 1.150 KILOHMS
IDENTICAL VALUE RESISTOR QUANTITY 1 LOWEST RESISTANCE VALUE 1 HIGHEST RESISTANCE VALUE 1 1ST INTERMEDIATE RESISTANCE VALUE 1 2ND INTERMEDIATE RESISTANCE VALUE 2 3RD INTERMEDIATE RESISTANCE VALUE
RESISTANCE TOLERANCE IN PERCENT -5.000 TO 5.000 -5.000 TO 5.000 -1.000 TO 1.000 -5.000 TO 5.000 -0.500 TO 0.500
POWER DISSIPATION RATING IN WATTS 0.600 TOTAL NETWORK
AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER NOT RATED
AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER NOT RATED
INCLOSURE METHOD ENCAPSULATED
STYLE DESIGNATOR 218 SINGLE INLINE
BODY LENGTH 1.000 INCHES MAXIMUM
BODY WIDTH 0.110 INCHES MAXIMUM
BODY HEIGHT 0.250 INCHES NOMINAL
TERMINAL TYPE PIN
TERMINAL QUANTITY 10
RELIABILITY INDICATOR NOT ESTABLISHED
TERMINAL LENGTH 0.180 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5905-01-077-2554

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Electro-static Discharge Susceptible:BESD sensitivity
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5905-01-077-2554

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each