NSN 5905-01-125-3988 MIL-R-39009/1, MILR390091, RER75F1782R
Product Details | INDUCTIVE WIRE WOUND FIXED RESISTOR
5905-01-125-3988 INC 37403 REINSTATED ON 010303~A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of high resistance wire (or ribbon) either wound on an insulated form or constructed so as to be self-supporting. The item must have inherent characteristics of inducing self-inductance. Opposition to current flow is an inherent property of the resistance wire and is manifested by the heat dissipation in the resistor. Excludes SUPPRESSOR, IGNITION INTERFERENCE. See also RESISTOR (1), FIXED, WIRE WOUND, NONINDUCTIVE.
Part Alternates: MIL-R-39009/1, MILR390091, RER75F1782R, 5905-01-125-3988, 01-125-3988, 5905011253988, 011253988
Electrical and Electronic Equipment Components | Resistors
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 27 JAN 1982 | 01-125-3988 | 37403 ( RESISTOR, FIXED, WIRE WOUND, INDUCTIVE ) |
Demand History | NSN 5905-01-125-3988
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| MILR390091 | 2007-10-290 | 5 | Turkey |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5905-01-125-3988
Related Products | NSN 5905-01-125-3988
Technical Data | NSN 5905-01-125-3988
| Characteristic | Specifications |
|---|---|
| III ELECTRICAL RESISTANCE | 17.800 KILOHMS |
| RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
| POWER DISSIPATION RATING IN WATTS | 10.000 FREE AIR |
| AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
| AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
| TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -30.0 TO 30.0 |
| TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0 TO 275.0 |
| INCLOSURE METHOD | ENCASED |
| STYLE DESIGNATOR | AXIAL TERMINAL (S) |
| BODY LENGTH | 1.938 INCHES NOMINAL |
| BODY WIDTH | 0.594 INCHES NOMINAL |
| BODY HEIGHT | 0.625 INCHES NOMINAL |
| DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 1.562 INCHES NOMINAL |
| MOUNTING HOLE SIZE | 0.125 INCHES NOMINAL |
| TERMINAL TYPE | TAB, SOLDER LUG |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
| TERMINAL LENGTH | 0.438 INCHES NOMINAL |
| TERMINAL WIDTH | 0.140 INCHES MINIMUM |
| TEST DATA DOCUMENT | 81349-MIL-R-39009 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
| SPECIFICATION/STANDARD DATA | 81349-MIL-R-39009/1 GOVERNMENT SPECIFICATION |
| MANUFACTURERS CODE | 81349 |
| NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-R-39009/1 |
| MANUFACTURERS CODE | 81349 |
| DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | RER75F1782R |
Restrictions/Controls & Freight Information | NSN 5905-01-125-3988
| Category | Code | Description |
|---|---|---|
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Electro-static Discharge Susceptible: | A | No known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 062960 | REOSTATS/PARTS NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | V | Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5905-01-125-3988
| Category | Code | Description |
|---|---|---|
| Stores Account Code | 1 | Marine Corps Stock Fund Account Item. |
| Combat Essentiality Code | 2 | Non-Critical Repair Part. Repair parts or major components whose failure in an end item will not render the end item inoperative or reduce its effectiveness below the minimum acceptable level of efficiency, and which do not fit the definition of Code 3 or 4 items. |
| Materiel Management Code | E | Electronics MaterielDefense Electronics Supply Center (DESC) |
| Echelon Management Code | 2 | ICP/DSSC Marine Corps-managed Recoverability Code D items and Defense Logistics Agency (DLA)/TACOM/GSA) items which the integrated manager has not decontrolled. |
| Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
| Agency | DM | U.S. Marine Corps |
| Service Organization | M | U.S. Marine Corps |
| Reparability | Z | Nonreparable item. When unserviceable, condemn and dispose at the level indicated by the first digit of the maintenance code. |
| Acquisition Advice Codes | D | DoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |