Product Details | THERMAL RESISTOR

5905-01-166-8031 A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.

Part Alternates: DS125502J, DS125-502J, QTM12502J, QTM12-502J, 7141135560, 714-1135-560, 5905-01-166-8031, 01-166-8031, 5905011668031, 011668031

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 17 NOV 1983 01-166-8031

Cross Reference | NSN 5905-01-166-8031

Part Number Cage Code Manufacturer
714-1135-560 13499 ROCKWELL COLLINS, INC. DBA GOVERNMENT SYSTEMS
DS125-502J 15454 RTIE HOLDINGS LLC
QTM12-502J 56866 QUALITY THERMISTOR INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-166-8031

Technical Data | NSN 5905-01-166-8031

Characteristic Specifications
ZERO POWER RESISTANCE 5.000 KILOHMS
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP -5.0 TO 5.0
MAXIMUM POWER DISSIPATION RATING 125.00 MILLIWATTS
AMBIENT TEMP AT FULL RATED POWER 100.0 DEG CELSIUS
MAXIMUM OPERATING TEMP 150.0 DEG CELSIUS
THERMAL TIME CONSTANT IN SECONDS 34.8
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS 3.0
ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS 2.14
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -80.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT -50.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT -20.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT 10.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT 40.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT 55.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT 70.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT 100.0 DEG CELSIUS 8TH RESISTANCE-TEMPERATURE POINT 130.0 DEG CELSIUS 9TH RESISTANCE-TEMPERATURE POINT 150.0 DEG CELSIUS 10TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP 2.25 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT 2.75 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT 3.4 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT 4.55 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT 5.75 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT 6.6 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT 7.3 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT 8.0 KILOHMS 8TH RESISTANCE-TEMPERATURE POINT 9.75 KILOHMS 9TH RESISTANCE-TEMPERATURE POINT 10.55 KILOHMS 10TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -16.0 TO 16.0 1ST RESISTANCE-TEMPERATURE POINT -13.0 TO 13.0 2ND RESISTANCE-TEMPERATURE POINT -9.0 TO 9.0 3RD RESISTANCE-TEMPERATURE POINT -6.0 TO 6.0 4TH RESISTANCE-TEMPERATURE POINT -8.0 TO 8.0 5TH RESISTANCE-TEMPERATURE POINT -10.0 TO 10.0 6TH RESISTANCE-TEMPERATURE POINT

Restrictions/Controls & Freight Information | NSN 5905-01-166-8031

Category Code Description
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable