Product Details | THERMAL RESISTOR

5905-01-211-9255 A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.

Part Alternates: 10676183, 5905-01-211-9255, 01-211-9255, 5905012119255, 012119255

Electrical and Electronic Equipment Components | Resistors

Supply Group (FSG) NSN Assign. NIIN
59 03 JUL 1985 01-211-9255

Demand History | NSN 5905-01-211-9255

Part Number Request Date QTY Origin
5905-01-211-9255 2016-01-13 1 DIBBS
5905-01-211-9255 2016-01-05 1 DIBBS
5905-01-211-9255 2015-10-299 1 DIBBS
5905-01-211-9255 2015-10-287 1 DIBBS
5905-01-211-9255 2012-08-222 2 DIBBS
5905-01-211-9255 2012-01-15 2 DIBBS
5905-01-211-9255 2011-12-349 2 DIBBS
5905-01-211-9255 2011-11-328 1 DIBBS
5905-01-211-9255 2011-07-210 2 DIBBS
5905-01-211-9255 2011-04-92 2 DIBBS
5905-01-211-9255 2010-03-62 42 DIBBS

Cross Reference | NSN 5905-01-211-9255

Part Number Cage Code Manufacturer
10676183 18876 U S ARMY AVIATION AND MISSILE COMMAND
10676183 56866 QUALITY THERMISTOR INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5905-01-211-9255

Technical Data | NSN 5905-01-211-9255

Characteristic Specifications
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -15.0 TO 15.0 1ST RESISTANCE-TEMPERATURE POINT
MAXIMUM OPERATING TEMP 125.0 DEG CELSIUS
ZERO POWER RESISTANCE AT SPECIFIED TEMP 4.3 KILOHMS 7TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 125.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -15.0 TO 15.0 7TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP 3.7 KILOHMS 6TH RESISTANCE-TEMPERATURE POINT
THERMAL TIME CONSTANT IN SECONDS 60.0
INCLOSURE TYPE ENCAPSULATED
ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP -5.0 TO 5.0
RELIABILITY INDICATOR NOT ESTABLISHED
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 75.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -7.0 TO 7.0 3RD RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -7.0 TO 7.0 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP 1.6 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -9.0 TO 9.0 2ND RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP 1.8 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT
STYLE DESIGNATOR ROD
ZERO POWER RESISTANCE AT SPECIFIED TEMP 2.7 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -9.0 TO 9.0 5TH RESISTANCE-TEMPERATURE POINT
POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS 2.5
AMBIENT TEMP AT FULL RATED POWER 25.0 DEG CELSIUS
BODY LENGTH 0.350 INCHES MAXIMUM
ZERO POWER RESISTANCE 2.000 KILOHMS
TERMINAL DIAMETER 0.025 INCHES NOMINAL
TERMINAL LENGTH 1.200 INCHES NOMINAL
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 50.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT
TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER 100.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT
BODY OUTSIDE DIAMETER 0.110 INCHES MAXIMUM
MAXIMUM POWER DISSIPATION RATING 0.25 WATTS
ZERO POWER RESISTANCE AT SPECIFIED TEMP 1.1 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT
RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT -12.0 TO 12.0 6TH RESISTANCE-TEMPERATURE POINT
ZERO POWER RESISTANCE AT SPECIFIED TEMP 3.2 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT
TERMINAL TYPE AND QUANTITY 2 WIRE LEAD

Restrictions/Controls & Freight Information | NSN 5905-01-211-9255

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeNThere is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 062960 REOSTATS/PARTS NOI
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code BD U.S. Army Aviation and Missile Command
Redstone Arsenal, AL 35898-5230
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5905-01-211-9255

Category Code Description
Materiel Category and Inventory ManagerQ Electronics Materiel (DLA/GSA Items)
Appropriation and Budget Activity2 Stock Fund Secondary Items
Management Inventory Segment2 NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable.
Specific Group/Generic Code0 Medical Materiel
Weapons Systems/End Item or Homogeneous Group00DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item
Accounting Requirements CodeX Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDADepartment of the Army
Service OrganizationAU.S. Army
ReparabilityZThis is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item.
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each