NSN 5905-01-225-8976 A10594, A30130201, A3013020-1
Product Details | THERMAL RESISTOR
5905-01-225-8976 A thermally sensitive resistor whose primary function is to exhibit a change in electrical resistance with a change in body temperature. Item may be mounted in a probe or housing. For ballast tube type resistors, see RESISTOR (1), CURRENT REGULATING. Excludes TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE and TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
Part Alternates: A10594, A30130201, A3013020-1, 5905-01-225-8976, 01-225-8976, 5905012258976, 012258976
Electrical and Electronic Equipment Components | Resistors
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 08 FEB 1986 | 01-225-8976 | 00309 ( RESISTOR, THERMAL ) |
Demand History | NSN 5905-01-225-8976
| Part Number | Request Date | QTY | Origin |
|---|---|---|---|
| 5905-01-225-8976 | 2007-01-24 | 5 | DIBBS |
Cross Reference | NSN 5905-01-225-8976
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5905-01-225-8976
Related Products | NSN 5905-01-225-8976
Technical Data | NSN 5905-01-225-8976
| Characteristic | Specifications |
|---|---|
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 120.75 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
| END ITEM IDENTIFICATION | SINCGARS |
| MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 47.9375 KILOHMS 4TH RESISTANCE-TEMPERATURE POINT |
| TERMINAL LENGTH | 1.500 INCHES MINIMUM |
| TEST DATA DOCUMENT | 80063-A3013020 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
| INCLOSURE TYPE | ENCAPSULATED |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -1.9 TO 1.9 3RD RESISTANCE-TEMPERATURE POINT |
| TERMINAL SURFACE TREATMENT | SOLDER |
| THERMAL TIME CONSTANT IN SECONDS | 2.0 |
| BODY WIDTH | 0.150 INCHES MAXIMUM |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 20.75 KILOHMS 5TH RESISTANCE-TEMPERATURE POINT |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.55 TO 0.55 1ST RESISTANCE-TEMPERATURE POINT |
| TERMINAL DIAMETER | 0.01003 INCHES NOMINAL |
| MAXIMUM POWER DISSIPATION RATING | 250.00 MILLIWATTS |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.1 TO 5.1 5TH RESISTANCE-TEMPERATURE POINT |
| STYLE DESIGNATOR | SPHERICAL |
| POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 2.0 |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -0.72 TO 0.72 2ND RESISTANCE-TEMPERATURE POINT |
| BODY OUTSIDE DIAMETER | 0.150 INCHES MAXIMUM |
| REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 365.625 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
| TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE | 1.250 MEGOHMS |
| RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -3.0 TO 3.0 4TH RESISTANCE-TEMPERATURE POINT |
| TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
| ZERO POWER RESISTANCE AT SPECIFIED TEMP | 5.09 MEGOHMS 1ST RESISTANCE-TEMPERATURE POINT |
| ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
Restrictions/Controls & Freight Information | NSN 5905-01-225-8976
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | N | There is no data in the HMIS and the NSN is in an FSC not generally suspected of containing hazardous materials |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 062960 | REOSTATS/PARTS NOI |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TH | Defense Supply Center Columbus Columbus, OH 43215 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5905-01-225-8976
| Category | Code | Description |
|---|---|---|
| Materiel Category and Inventory Manager | Q | Electronics Materiel (DLA/GSA Items) |
| Appropriation and Budget Activity | 2 | Stock Fund Secondary Items |
| Management Inventory Segment | 2 | NONREPARABLE ITEMS (Exclusive of Insurance and Provisioning Items). This code will be used to identify items which are not reparable. |
| Specific Group/Generic Code | 0 | Medical Materiel |
| Weapons Systems/End Item or Homogeneous Group | 00 | DLA/GSA-Managed Items that cannot be identified to a specific Army Weapons Systems/End Item |
| Accounting Requirements Code | X | Expendable item. An item of Army property coded with an ARC of ?X? in the AMDF. Expendable items require no formal accountability after issue from a stock record account. Commercial and fabricated items similar to items coded ?X? in the AMDF are considered expendable items. |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DA | Department of the Army |
| Service Organization | A | U.S. Army |
| Reparability | Z | This is a nonreparable item. If condemned or economically unserviceable, then dispose at the level authorized replace the item. |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |