Product Details | GLASS DIELECTRIC FIXED CAPACITOR

5910-00-082-4771 A capacitor, whose capacitance value cannot be adjusted or varied, having a glass (silicas) or glass like substance (e.g., porcelain, vitreous enamel) as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: CL65CL150KP3, MILC39654, MILC3965-4 , VY12C121JF, 5910-00-082-4771, 00-082-4771, 5910000824771, 000824771

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1961 00-082-4771

Drawings & Photos | NSN 5910-00-082-4771


Cross Reference | NSN 5910-00-082-4771

Part Number Cage Code Manufacturer
VY12C121JF 95275 VITRAMON INC PO BOX 544 BRIDGEPORT CT 06601

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-082-4771

Technical Data | NSN 5910-00-082-4771

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 120.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -5.00 TO 5.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 500.0 DC SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS 105.0 SINGLE SECTION
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS -25.0 TO 25.0 SINGLE SECTION
NONDERATED OPERATING TEMP -65.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 29A W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
BODY LENGTH 0.375 INCHES NOMINAL
BODY WIDTH 0.188 INCHES NOMINAL
BODY HEIGHT 0.156 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.125 INCHES MINIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.285 INCHES MINIMUM AND 0.315 INCHES MAXIMUM
CASE MATERIAL GLASS
INSULATION RESISTANCE AT REFERENCE TEMP 100000.0 MEGOHMS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 0.0006
QUALITY FACTOR AT REFERENCE TEMP 2500.0000
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
(NON-CORE DATA) OVERALL LENGTH 0.375 INCHES NOMINAL
III INSULATION RESISTANCE AT MAXIMUM OPERATING TEMP 10000.0 MEGOHMS
(NON-CORE DATA) OVERALL HEIGHT 0.156 INCHES NOMINAL
(NON-CORE DATA) OVERALL WIDTH 0.188 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5910-00-082-4771

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable