Product Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-00-121-9384 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: A77212D, A77-212-D, CER1261212, CER1261-212, CK31BT222J, CYK01BT221J, CYK01BT222JY, SEC 6019-212, SEC6019212, SK1261212, SK1261-212, E 0877-212, E0877212, 4410877212, 441-0877-212, 5910-00-121-9384, 00-121-9384, 5910001219384, 001219384

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 30 OCT 1968 00-121-9384

Drawings & Photos | NSN 5910-00-121-9384


Cross Reference | NSN 5910-00-121-9384

Part Number Cage Code Manufacturer
441-0877-212 94756 BOEING COMPANY, THE DBA BOEING
A77-212-D 96095 AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS
CER1261-212 14158 AVX FILTERS
CK31BT222J 16299 AVX CORP RALEIGH PLANT
CYK01BT221J 16299 AVX CORP RALEIGH PLANT
CYK01BT222JY 16299 AVX CORP RALEIGH PLANT
E 0877-212 72982 ERIE SPECIALTY PRODUCTS INC
SEC 6019-212 99217 BELL INDUSTRIES INC ELECTRONIC DISTRIBUTOR DIV
SK1261-212 14158 AVX FILTERS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-121-9384

Technical Data | NSN 5910-00-121-9384

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 2200.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -5.00 TO 5.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 100.0 DC SINGLE SECTION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE -30.0 TO 10.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.100 INCHES MAXIMUM
BODY LENGTH 0.275 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.250 INCHES MINIMUM
TERMINAL DIAMETER 0.015 INCHES MINIMUM AND 0.026 INCHES MAXIMUM
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP 20000.0 MEGOHMS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 2.5000
RELIABILITY INDICATOR NOT ESTABLISHED
III MIL-STD-1276 WIRE LEAD TYPE DESIGNATOR N-2
III TERMINAL SURFACE TREATMENT SOLDER
(NON-CORE DATA) OVERALL LENGTH 0.275 INCHES MAXIMUM
(NON-CORE DATA) OVERALL HEIGHT 0.100 INCHES MAXIMUM
(NON-CORE DATA) OVERALL WIDTH 0.100 INCHES MAXIMUM
MANUFACTURERS CODE 94756
DESIGN CONTROL REFERENCE 441-0877-212

Restrictions/Controls & Freight Information | NSN 5910-00-121-9384

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code SG 403 SCMS/GUED
5215 Thurlow St, Suite 5, Bldg 70C
Wright-Patterson AFB OH 45433
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable