Product Details | GLASS DIELECTRIC FIXED CAPACITOR

5910-00-153-5719 A capacitor, whose capacitance value cannot be adjusted or varied, having a glass (silicas) or glass like substance (e.g., porcelain, vitreous enamel) as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: 0N1432823145, 0N143282-3145, 5910-00-153-5719, 00-153-5719, 5910001535719, 001535719

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 18 OCT 1971 00-153-5719

Drawings & Photos | NSN 5910-00-153-5719


Cross Reference | NSN 5910-00-153-5719

Part Number Cage Code Manufacturer
0N143282-3145 98230 NATIONAL SECURITY AGENCY

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-153-5719

Technical Data | NSN 5910-00-153-5719

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 82.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -5.00 TO 5.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 500.0 DC SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS 0.0 SINGLE SECTION
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS -25.0 TO 25.0 SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 21A W/O MTG FACILITIES, TERMINALS ON OPPOSITE SURFACES
BODY LENGTH 0.390 INCHES NOMINAL
BODY WIDTH 0.109 INCHES NOMINAL
BODY HEIGHT 0.200 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.125 INCHES NOMINAL
CASE MATERIAL GLASS
INSULATION RESISTANCE AT REFERENCE TEMP 100000.0 MEGOHMS
RELIABILITY INDICATOR NOT ESTABLISHED
FEATURES PROVIDED HERMETICALLY SEALED CASE

Restrictions/Controls & Freight Information | NSN 5910-00-153-5719

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XN National Security Agency
ATTN: L111
Fort George G. Meade, MD 20755-6000
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-00-153-5719

Category Code Description
Materiel Management Aggregation CodeCSSJ:COMMUNICATIONS SECURITY (COMSEC) OTHER THAN SERIALIZED CONTROL ITEM
Budget CodeK 8357X3080:Cryptologic and Other USAF Security Service Equipment
Fund CodeROMajor repair.
Price ValidationV The current standard price has been validated.
  • The item has been analyzed in conjunction with the Zero Overpricing Program and is in the accepted price range.
  • The item was procured under open competition and under the competitive arena the price is considered fair and reasonable.
  • ZOP or Standard price challenges are permissible but must be supported by adequate justification.
Source of SupplyFPDAir Force Cryptologic Support Center (ESC)
San Antonio, TX 78243-5000
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesMRESTRICTED REQUISITIONS-MAJOR OVERHAUL (Service/Agency use only.) # Items (Assemblies and/or component parts) which for lack of specialized tools, test equipment, etc., can be used only by major overhaul activities. Base, post, camp or station activities will not requisition unless authorized to perform major overhaul function.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each