Product Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-00-175-5851 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: SR201A390GAA, RPE121C0G390G100V, 200100NP0390G, 200-100-NP0-390G, 3429100A390G, 3429-100A390G, 8121100C0G390G, 8121-100C0G390G, 8121-100-C0G-390G, 8121A100C0G0390G, 5910-00-175-5851, 00-175-5851, 5910001755851, 001755851

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 08 DEC 1971 00-175-5851

Drawings & Photos | NSN 5910-00-175-5851


Cross Reference | NSN 5910-00-175-5851

Part Number Cage Code Manufacturer
200-100-NP0-390G 51642 CENTRE CAPACITOR INC
3429-100A390G 04222 AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS
8121-100-C0G-390G 59660 TUSONIX, INC.
8121-100C0G390G 72982 ERIE SPECIALTY PRODUCTS INC
8121A100C0G0390G 18796 MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS
8121A100C0G0390G 72982 ERIE SPECIALTY PRODUCTS INC
RPE121C0G390G100V 18796 MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS
SR201A390GAA 04222 AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-175-5851

Technical Data | NSN 5910-00-175-5851

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 39.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -2.00 TO 2.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 100.0 DC SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS 0.0 SINGLE SECTION
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS -30.0 TO 30.0 SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 150.0 DEG CELSIUS MAXIMUM
BODY STYLE 27A W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH 0.200 INCHES MAXIMUM
BODY WIDTH 0.200 INCHES MAXIMUM
BODY HEIGHT 0.125 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.500 INCHES MINIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.169 INCHES MINIMUM AND 0.231 INCHES MAXIMUM
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP 100000.0 MEGOHMS
QUALITY FACTOR AT REFERENCE TEMP 1000.0000
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER

Restrictions/Controls & Freight Information | NSN 5910-00-175-5851

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable