NSN 5910-00-225-2131 MD10414N, CET3A135SP, 641237
Product Details | MICA DIELECTRIC FIXED CAPACITOR
5910-00-225-2131 A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.
Part Alternates: MD10414N, CET3A135SP, 641237, 6-41237, 4949341, 494934-1, 5910-00-225-2131, 00-225-2131, 5910002252131, 002252131
Electrical and Electronic Equipment Components | Capacitors
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 27 MAR 1970 | 00-225-2131 | 00005 ( CAPACITOR, FIXED, MICA DIELECTRIC ) |
Cross Reference | NSN 5910-00-225-2131
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 494934-1 | 96214 | RAYTHEON COMPANY DBA RAYTHEON |
| 6-41237 | 28839 | TELEDYNE INDUSTRIES INC TELEDYNE POWER SYSTEMS DIV |
| 6-41237 | 59501 | UNISON INDUSTRIES, LLC |
| 6-41237 | 77820 | AMPHENOL CORPORATION DBA AMPHENOL AEROSPACE INDUSTRIAL |
| CET3A135SP | 23280 | CUSTOM ELECTRONICS, INC. |
| MD10414N | 13058 | SORA POWER INC. |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5910-00-225-2131
Related Products | NSN 5910-00-225-2131
Technical Data | NSN 5910-00-225-2131
| Characteristic | Specifications |
|---|---|
| CAPACITANCE VALUE PER SECTION | 0.100 MICROFARADS SINGLE SECTION |
| TOLERANCE RANGE PER SECTION | -10.00 TO 10.00 PERCENT SINGLE SECTION |
| NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 5000.0 DC SINGLE SECTION |
| NONDERATED OPERATING TEMP | -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM |
| BODY STYLE | 26B W/O MTG FACILITIES, AXIAL TERMINALS |
| BODY DIAMETER | 1.250 INCHES NOMINAL |
| BODY LENGTH | 3.375 INCHES MAXIMUM |
| SCHEMATIC DIAGRAM DESIGNATOR | 1C NO COMMON OR GROUNDED ELECTRODE(S) |
| TERMINAL TYPE AND QUANTITY | 2 THREADED STUD |
| TERMINAL LENGTH | 0.375 INCHES MAXIMUM |
| TERMINAL DIAMETER | 0.164 INCHES NOMINAL |
| CASE MATERIAL | PLASTIC |
| RELIABILITY INDICATOR | NOT ESTABLISHED |
| (NON-CORE DATA) OVERALL LENGTH | 4.375 INCHES MAXIMUM |
| (NON-CORE DATA) OVERALL HEIGHT | 1.250 INCHES NOMINAL |
| (NON-CORE DATA) OVERALL WIDTH | 1.250 INCHES NOMINAL |
Restrictions/Controls & Freight Information | NSN 5910-00-225-2131
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | U | Precious metal type is unknown |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061400 | CONDENSERS/PARTS NOI/CAPACITORS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 658 | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5910-00-225-2131
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9N | Navy-owned stocks of defense electronic material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | S9E | Defense Supply Center Columbus Columbus, OH 43218 |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | V | TERMINAL ITEM # Identifies items in stock, but future procurement is not authorized. Requisitions may continue to be submitted until stocks are exhausted. Preferred item National Stock Number is normally provided by application of the phrase: When Exhausted Use (NSN). Requisitions will be submitted in accordance with IMM/Service requisitioning procedures as applicable. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |