Product Details | MICA DIELECTRIC FIXED CAPACITOR

5910-00-442-9125 A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: 3178809, 5910-00-442-9125, 00-442-9125, 5910004429125, 004429125

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 28 MAR 1969 00-442-9125

Drawings & Photos | NSN 5910-00-442-9125


Cross Reference | NSN 5910-00-442-9125

Part Number Cage Code Manufacturer
3178809 16623 UNITED STATES DEPARTMENT OF THE NAVY DBA NAVAL UNDERSEA WARFARE CTR DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-442-9125

Technical Data | NSN 5910-00-442-9125

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 30.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -0.00 TO 2.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 100.0 DC SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE RANGE PER SECTION IN PPM PER DEG CELSIUS -0.0 TO 70.0 SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 27A W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH 0.750 INCHES MAXIMUM
BODY WIDTH 0.820 INCHES MAXIMUM
BODY HEIGHT 0.360 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.250 INCHES MINIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.440 INCHES NOMINAL
CASE MATERIAL PLASTIC
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
MANUFACTURERS CODE 16623
DESIGN CONTROL REFERENCE 3178809

Restrictions/Controls & Freight Information | NSN 5910-00-442-9125

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:NThe item does not have a critical feature such as tolerance, fit restrictions or application. Nuclear hardness properties have not been determined (not valid for input).
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating M 85
Less than truck load rating P 77.5
Water commodity Code 671 unknown
Originating Activity Code TG Warner-Robins Air Logistics Center
Robins AFB, GA 31098-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity V Vehicles, machinery, shop and warehouse equipment and supplies, including special tools and equipment, ground servicing and special purpose vehicles, marine equipment and supplies, repair and maintenance parts for the above.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-00-442-9125

Category Code Description
Materiel Management Aggregation CodeCWTG:AIRBORNE RADAR AND MISCELLANEOUS ELECTRONIC EQUIPMENT
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityPStock Fund (except Munitions)
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9FNavy-owned stocks of material managed by the Air Force within the Warner Robins Air Logistics Center
Naval Inventory Control Point, Mechanicsburg
Issue Repair, or RequisitionR9Integrated Manager reparable item. Includes Defense Logistics Agency-managed items which are reportable in non-RFI condition to appropriate Defense Supply Center per NAVSUP instructions for return of excess material to DLA.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each