Product Details | PAPER DIELECTRIC FIXED CAPACITOR

5910-00-556-0701 A capacitor whose capacitance value cannot be adjusted or varied, having paper as the dielectric material. It may be a single unit or consist of two or more fixed units which cannot be seperated. For items whose dielectric material consist of plasticized (plastic impregnated) paper or paper-plastic combinations, see CAPACITOR, FIXED, PLASTIC DIELECTRIC. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALIZED, PAPER-PLASTIC DIELECTRIC.

Part Alternates: 995A2020, 995-A-2020, 5910-00-556-0701, 00-556-0701, 5910005560701, 005560701

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 00-556-0701

Drawings & Photos | NSN 5910-00-556-0701


Cross Reference | NSN 5910-00-556-0701

Part Number Cage Code Manufacturer
995-A-2020 83777 E-SYSTEMS INC MEMCOR DIV FLORIDA OPNS
CP05A2EE303K 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
CQ05A3KE333K3 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MIL-C-19978/19 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
PC0313 06141 L-3 COMMUNICATIONS CORPORATION DBA L-3 COMMUNICATIONS AVIATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-556-0701

Technical Data | NSN 5910-00-556-0701

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 33000.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 200.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.312 INCHES NOMINAL
BODY LENGTH 0.875 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 3C ELECTRODE(S) GROUNDED TO CASE, W/GND TERMINAL
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 2.438 INCHES NOMINAL
TERMINAL DIAMETER 0.025 INCHES NOMINAL
CASE MATERIAL METAL
RELIABILITY INDICATOR NOT ESTABLISHED
FEATURES PROVIDED HERMETICALLY SEALED CASE
III TERMINAL SURFACE TREATMENT SOLDER

Restrictions/Controls & Freight Information | NSN 5910-00-556-0701

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Category Code Description
No Freight Information