Product Details | MICA DIELECTRIC FIXED CAPACITOR

5910-00-588-5786 A capacitor, whose capacitance value cannot be adjusted or varied, having natural sheet mica or reconstituted flaked mica formed into sheets as the dielectric material. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: 578R886H01, 5910-00-588-5786, 00-588-5786, 5910005885786, 005885786

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 28 DEC 1974 00-588-5786

Drawings & Photos | NSN 5910-00-588-5786


Cross Reference | NSN 5910-00-588-5786

Part Number Cage Code Manufacturer
578R886H01 97942 NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-588-5786

Technical Data | NSN 5910-00-588-5786

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 1.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 1000.0 DC SINGLE SECTION
BODY STYLE 13A W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
BODY LENGTH 2.000 INCHES MAXIMUM
BODY WIDTH 0.400 INCHES MAXIMUM
BODY HEIGHT 2.938 INCHES MAXIMUM
TERMINAL TYPE AND QUANTITY 2 THREADED STUD
TERMINAL LENGTH 0.438 INCHES MAXIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.938 INCHES NOMINAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 0.5000
RELIABILITY INDICATOR NOT ESTABLISHED

Restrictions/Controls & Freight Information | NSN 5910-00-588-5786

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TA Sacramento Air Logistics Center
McClellan AFB, CA 95652-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable