Product Details | PAPER-PLASTIC DIELECTRI METALLIZED FIXED CAPACITOR

5910-00-594-7986 A capacitor whose capacitance value cannot be adjusted or varied having paper, plastic, or any combination of paper and plastic as the dielectric material with a metallic film deposited thereon. It may be a single unit or consist of two or more units which cannot be separated.

Part Alternates: 21F880G202, 97F6763, 5910-00-594-7986, 00-594-7986, 5910005947986, 005947986

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-594-7986

Drawings & Photos | NSN 5910-00-594-7986


Cross Reference | NSN 5910-00-594-7986

Part Number Cage Code Manufacturer
21F880G202 01002 GENERAL ELECTRIC CO CAPACITORS DIV
97F6763 01002 GENERAL ELECTRIC CO CAPACITORS DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-594-7986

Technical Data | NSN 5910-00-594-7986

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 10.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -6.00 TO 6.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 330.0 AC-RMS SINGLE SECTION
TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS 0.0 SINGLE SECTION
TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS -5.0 TO 5.0 SINGLE SECTION
NONDERATED OPERATING TEMP -40.0 DEG CELSIUS MINIMUM AND 70.0 DEG CELSIUS MAXIMUM
BODY STYLE 13A W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
BODY LENGTH 2.690 INCHES NOMINAL
BODY WIDTH 1.560 INCHES NOMINAL
BODY HEIGHT 3.880 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 QUICK DISCONNECT, MALE, DOUBLE BLADE
TERMINAL LENGTH 0.630 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.810 INCHES NOMINAL
CASE MATERIAL METAL
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 0.100
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
(NON-CORE DATA) OVERALL LENGTH 2.690 INCHES NOMINAL
(NON-CORE DATA) OVERALL HEIGHT 4.510 INCHES MINIMUM
(NON-CORE DATA) OVERALL WIDTH 1.560 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5910-00-594-7986

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeYInformation is in the Hazardous Materials Information System (HMIS)
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Hazardous Control Code:Z3Article Containing Polychlorinated Biphenyl (PCB) ARTICLE, PCB
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-00-594-7986

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesXSEMIACTIVE ITEM-NO REPLACEMENT (NON-STOCKED ITEMS) A potentially inactive NSN which must be retained in the supply system as an item of supply because (1) stocks of the item are on hand or in use below the wholesale level and (2) the NSN is cited in equipment authorization documents TO & E, TA, TM, etc., or in-use assets are being reported. 1. Items are authorized for central procurement but not authorized for stockage at wholesale level. 2. Requisitions for in-use replacement will be authorized in accordance with individual Military Service directives. 3. Requisitions may be submitted as requirements generate. Repetitive demands may dictate an AAC change to permit wholesale stockage.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each