Product Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-00-607-7060 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: 581R395H02, 5910-00-607-7060, 00-607-7060, 5910006077060, 006077060

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 30 JAN 1975 00-607-7060

Drawings & Photos | NSN 5910-00-607-7060


Cross Reference | NSN 5910-00-607-7060

Part Number Cage Code Manufacturer
581R395H02 97942 NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NORTHROP GRUMMAN SYSTEMS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-607-7060

Technical Data | NSN 5910-00-607-7060

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 50000.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -0.00 TO 100.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 100.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 54B W/THD MTG BUSHING, TERMINALS ON OPPOSITE ENDS
WIDTH ACROSS FLATS 0.187 INCHES NOMINAL
BODY LENGTH 0.374 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 17C FEEDTHROUGH
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 0.187 INCHES NOMINAL
TERMINAL DIAMETER 0.040 INCHES NOMINAL
CASE MATERIAL METAL
MOUNTING FACILITY TYPE AND QUANTITY 1 THREADED BUSHING
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNF
NOMINAL THREAD SIZE 0.164 INCHES
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 4.0000
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT 97942-581R395 DRAWING
MANUFACTURERS CODE 97942
DESIGN CONTROL REFERENCE 581R395H02

Restrictions/Controls & Freight Information | NSN 5910-00-607-7060

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TA Sacramento Air Logistics Center
McClellan AFB, CA 95652-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code Z unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable