Product Details | PAPER DIELECTRIC FIXED CAPACITOR

5910-00-667-9027 A capacitor whose capacitance value cannot be adjusted or varied, having paper as the dielectric material. It may be a single unit or consist of two or more fixed units which cannot be seperated. For items whose dielectric material consist of plasticized (plastic impregnated) paper or paper-plastic combinations, see CAPACITOR, FIXED, PLASTIC DIELECTRIC. For items whose electrodes consist of a metallic film deposited (metallized) on the dielectric material, see CAPACITOR, FIXED, METALIZED, PAPER-PLASTIC DIELECTRIC.

Part Alternates: G320021S4, 03125750, 23F1005FB, 24F725, 5910-00-667-9027, 00-667-9027, 5910006679027, 006679027

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 01 JAN 1963 00-667-9027

Drawings & Photos | NSN 5910-00-667-9027


Cross Reference | NSN 5910-00-667-9027

Part Number Cage Code Manufacturer
03125750 30669 E AND R ELECTRONICS INC DBA DUMONT OSCILLOSCOPE
03125750 72314 BAE SYSTEMS INFORMATION AND ELECTRONIC SYSTEMS INTEGRATION I
23F1005FB 01002 GENERAL ELECTRIC CO CAPACITORS DIV
24F725 01002 GENERAL ELECTRIC CO CAPACITORS DIV
G320021S4 24930 EXELIS INC. DBA RADAR, RECONNAISSANCE & UNDERSEA

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-667-9027

Technical Data | NSN 5910-00-667-9027

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 25.000 MICROFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.00 TO 10.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 400.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
BODY STYLE 14A W/O MTG FACILITIES, TERMINAL(S) ON ONE SURFACE
BODY LENGTH 3.750 INCHES NOMINAL
BODY WIDTH 1.750 INCHES NOMINAL
BODY HEIGHT 4.750 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG
CASE MATERIAL METAL
RELIABILITY INDICATOR NOT ESTABLISHED
FEATURES PROVIDED HERMETICALLY SEALED CASE
(NON-CORE DATA) OVERALL LENGTH 3.750 INCHES NOMINAL
(NON-CORE DATA) OVERALL WIDTH 1.750 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5910-00-667-9027

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodeYInformation is in the Hazardous Materials Information System (HMIS)
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code XX
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-00-667-9027

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each
Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each