Product Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-00-999-4570 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: CK0T331M, CT10A331M, CT10-A-331M, EL50AT331M, 1860104-37, 262C067331X0500B, 5910-00-999-4570, 00-999-4570, 5910009994570, 186010437, 009994570

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 11 FEB 1966 00-999-4570

Drawings & Photos | NSN 5910-00-999-4570


Cross Reference | NSN 5910-00-999-4570

Part Number Cage Code Manufacturer
1860104-37 05397 UNION CARBIDE CORP MATERIALS SYSTEMS DIV
1860104-37 16546 MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
1860104-37 19315 HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS FORMER BENDIX NAVIGATION AND
1860104-37 55972 HONEYWELL INTL INC DEFENSE AVIONICS SYSTEMS
262C067331X0500B 56289 SPRAGUE ELECTRIC CO WORLD HQS
CK0T331M 14158 AVX FILTERS
CT10-A-331M 50056 PIEZOTHERMX CORPORATION
EL50AT331M 20932 ILLINOIS TOOL WORKS INC EMCON DIV

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-00-999-4570

Technical Data | NSN 5910-00-999-4570

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 330.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -20.00 TO 20.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 50.0 DC SINGLE SECTION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE -15.0 TO 15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 26B W/O MTG FACILITIES, AXIAL TERMINALS
BODY DIAMETER 0.090 INCHES MINIMUM AND 0.110 INCHES MAXIMUM
BODY LENGTH 0.255 INCHES MINIMUM AND 0.275 INCHES MAXIMUM
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.250 INCHES MINIMUM
TERMINAL DIAMETER 0.025 INCHES NOMINAL
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP 1000.0 MEGOHM-MICROFARADS
POWER FACTOR AT REFERENCE TEMP IN PERCENT 2.5000
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT 19315-1860104 DRAWING
III TERMINAL SURFACE TREATMENT SOLDER
MANUFACTURERS CODE 55972
DESIGN CONTROL REFERENCE 1860104-37

Restrictions/Controls & Freight Information | NSN 5910-00-999-4570

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating P 77.5
Less than truck load rating P 77.5
Water commodity Code 658 unknown
Originating Activity Code KE Naval ICP
Philadelphia, PA 19111
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable