Product Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-01-031-9879 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: C315C561M5R5CA, CN20A561M3, SR151C561MAA, G504BX561M, RPE111120X7R561M50V, RPE111-120X7R561M50V, 01603789, 0160-3789, 1C10X7R561M100B, 200050X7R561M, 200-050-X7R-561M, 8121-B138 X7R 561M, 8121B138X7R561M, 8121-B138-X7R-561M, 5910-01-031-9879, 01-031-9879, 5910010319879, 010319879

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 05 DEC 1976 01-031-9879

Drawings & Photos | NSN 5910-01-031-9879


Cross Reference | NSN 5910-01-031-9879

Part Number Cage Code Manufacturer
0160-3789 1LQK8 KEYSIGHT TECHNOLOGIES, INC.
0160-3789 28480 HEWLETT-PACKARD COMPANY DBA HEWLETT-PACKARD CO. OR HP
1C10X7R561M100B 56289 SPRAGUE ELECTRIC CO WORLD HQS
200-050-X7R-561M 51642 CENTRE CAPACITOR INC
8121-B138 X7R 561M 59660 TUSONIX, INC.
8121-B138-X7R-561M 18796 MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS
8121-B138-X7R-561M 72982 ERIE SPECIALTY PRODUCTS INC
C315C561M5R5CA 05397 UNION CARBIDE CORP MATERIALS SYSTEMS DIV
CN20A561M3 71590 CRL COMPONENTS INC
G504BX561M 96733 SFE TECHNOLOGIES
RPE111-120X7R561M50V 18796 MURATA ERIE NORTH AMERICA INC STATE COLLEGE OPNS
RPE111-120X7R561M50V 72982 ERIE SPECIALTY PRODUCTS INC
SR151C561MAA 04222 AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-031-9879

Technical Data | NSN 5910-01-031-9879

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 560.000 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -20.00 TO 20.00 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 50.0 DC SINGLE SECTION
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE -15.0 TO 15.0 WITHOUT VOLTAGE APPLIED SINGLE SECTION
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 125.0 DEG CELSIUS MAXIMUM
BODY STYLE 27A W/O MTG FACILITIES TERMINAL(S) ON ONE SURFACE
BODY LENGTH 0.145 INCHES NOMINAL
BODY WIDTH 0.145 INCHES NOMINAL
BODY HEIGHT 0.095 INCHES NOMINAL
SCHEMATIC DIAGRAM DESIGNATOR 1C NO COMMON OR GROUNDED ELECTRODE(S)
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
TERMINAL LENGTH 1.250 INCHES MINIMUM
TERMINAL DIAMETER 0.020 INCHES NOMINAL
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 0.100 INCHES NOMINAL
CASE MATERIAL PLASTIC
INSULATION RESISTANCE AT REFERENCE TEMP 1000.0 MEGOHM-MICROFARADS
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 2.5000
RELIABILITY INDICATOR NOT ESTABLISHED
III TERMINAL SURFACE TREATMENT SOLDER
(NON-CORE DATA) OVERALL LENGTH 0.145 INCHES NOMINAL
(NON-CORE DATA) OVERALL HEIGHT 0.095 INCHES NOMINAL
(NON-CORE DATA) OVERALL WIDTH 0.145 INCHES NOMINAL

Restrictions/Controls & Freight Information | NSN 5910-01-031-9879

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061400 CONDENSERS/PARTS NOI/CAPACITORS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5910-01-031-9879

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesYTERMINAL ITEM #(NON-STOCKED ITEMS) Future procurement is not authorized. No wholesale stock is available for issue. 1. Requisitions will not be processed to the wholesale manager. 2. Internal Service/agency requisitioning may be continued in accordance with the Service/agency requisitioning policies.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative