Product Details | CERAMIC DIELECTRIC FIXED CAPACITOR

5910-01-187-7956 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: 831000X5F0102K, 831-000X5F0102K, 5910-01-187-7956, 01-187-7956, 5910011877956, 011877956

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 25 AUG 1984 01-187-7956

Cross Reference | NSN 5910-01-187-7956

Part Number Cage Code Manufacturer
831-000X5F0102K 59660 TUSONIX, INC.
831-000X5F0102K 72982 ERIE SPECIALTY PRODUCTS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-187-7956

Technical Data | NSN 5910-01-187-7956

Characteristic Specifications
INSULATION RESISTANCE AT REFERENCE TEMP 10000.0 MEGOHMS
TERMINAL LENGTH 1.500 INCHES MINIMUM
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER 0.250 INCHES NOMINAL
TOLERANCE RANGE PER SECTION -10.00/+10.00 PERCENT SINGLE SECTION
TERMINAL SURFACE TREATMENT SOLDER
DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT 2.0000
RELIABILITY INDICATOR NOT ESTABLISHED
CASE MATERIAL PLASTIC
BODY DIAMETER 0.290 INCHES MAXIMUM
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 500.0 DC SINGLE SECTION
TERMINAL TYPE AND QUANTITY 2 UNINSULATED WIRE LEAD
CAPACITANCE VALUE PER SECTION 1000.000 PICOFARADS SINGLE SECTION
SCHEMATIC DIAGRAM DESIGNATOR NO COMMON OR GROUNDED ELECTRODE(S)
BODY LENGTH 0.156 INCHES MAXIMUM
NONDERATED OPERATING TEMP -55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM
TERMINAL DIAMETER 0.025 INCHES NOMINAL
VOLTAGE TEMP LIMITS PER SECTION IN PERCENT CAPACITANCE CHANGE -4.7/+4.7 WITH 500 VOLTS APPLIED SINGLE SECTION
BODY STYLE W/O MTG FACILITIES, RADIAL TERMINALS

Restrictions/Controls & Freight Information | NSN 5910-01-187-7956

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
No Freight Information