Product Details | CERAMIC DIELECTR FIXED CAPACITOR

5910-01-595-2564 A capacitor, whose capacitance value cannot be adjusted or varied, having a ceramic dielectric. It may be a single unit, or consist of two or more fixed units which cannot be separated.

Part Alternates: TAJE476K035, 5910-01-595-2564, 01-595-2564, 5910015952564, 015952564

Electrical and Electronic Equipment Components | Capacitors

Supply Group (FSG) NSN Assign. NIIN
59 25 APR 2011 01-595-2564

Cross Reference | NSN 5910-01-595-2564

Part Number Cage Code Manufacturer
TAJE476K035 04222 AVX CORPORATION DBA OLEAN ADVANCED PRODUCTS

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5910-01-595-2564

Technical Data | NSN 5910-01-595-2564

Characteristic Specifications
CAPACITANCE VALUE PER SECTION 47.0 PICOFARADS SINGLE SECTION
TOLERANCE RANGE PER SECTION -10.0 TO 10.0 PERCENT SINGLE SECTION
NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION 35.0 DC SINGLE SECTION
NONDERATED OPERATING TEMP 55.0 DEG CELSIUS MINIMUM AND
BODY STYLE W/THD MTG HOLE(S)/STUD(S), TERMINAL(S) ON ONE SURFACE
BODY LENGTH 0.287 INCHES NOMINAL
BODY WIDTH 0.169 INCHES NOMINAL
BODY HEIGHT 0.162 INCHES NOMINAL
TERMINAL TYPE AND QUANTITY 2 TAB, SOLDER LUG
RELIABILITY INDICATOR NOT ESTABLISHED
III PART NAME ASSIGNED BY CONTROLLING AGENCY STANDARD TANTALUM

Restrictions/Controls & Freight Information | NSN 5910-01-595-2564

Category Code Description
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Electro-static Discharge Susceptible:ANo known Electrostatic Discharge (ESD) or Electromagnetic Interference (EMI) sensitivity
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
No Freight Information