Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-00-081-9939 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: 10133425-2, 5915-00-081-9939, 00-081-9939, 5915000819939, 101334252, 000819939

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 20 DEC 1967 00-081-9939

Drawings & Photos | NSN 5915-00-081-9939


Cross Reference | NSN 5915-00-081-9939

Part Number Cage Code Manufacturer
10133425-2 18876 U S ARMY AVIATION AND MISSILE COMMAND

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-081-9939

Technical Data | NSN 5915-00-081-9939

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE 50.0 OHMS 6TH RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE 50.0 OHMS 4TH RADIO INTERFERENCE 50.0 OHMS 5TH RADIO INTERFERENCE 50.0 OHMS 6TH RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 500.0 VOLTS DC 1ST RADIO INTERFERENCE 500.0 VOLTS DC 2ND RADIO INTERFERENCE 500.0 VOLTS DC 3RD RADIO INTERFERENCE 500.0 VOLTS DC 4TH RADIO INTERFERENCE 500.0 VOLTS DC 5TH RADIO INTERFERENCE 500.0 VOLTS DC 6TH RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 0.5 1ST RADIO INTERFERENCE 0.5 2ND RADIO INTERFERENCE 0.5 3RD RADIO INTERFERENCE 0.5 4TH RADIO INTERFERENCE 0.5 5TH RADIO INTERFERENCE 0.5 6TH RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION 5.0 VOLTS DC 1ST RADIO INTERFERENCE 5.0 VOLTS DC 2ND RADIO INTERFERENCE 5.0 VOLTS DC 3RD RADIO INTERFERENCE 5.0 VOLTS DC 4TH RADIO INTERFERENCE 5.0 VOLTS DC 5TH RADIO INTERFERENCE 5.0 VOLTS DC 6TH RADIO INTERFERENCE
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 1 CONNECTOR, RECEPTACLE OUTPUT
STYLE DESIGNATOR 27 RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES
OVERALL LENGTH 1.950 INCHES NOMINAL
OVERALL HEIGHT 1.110 INCHES NOMINAL
BODY LENGTH 1.635 INCHES NOMINAL
BODY HEIGHT 1.000 INCHES NOMINAL
BODY WIDTH 1.150 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 2 TERMINAL
SPECIAL FEATURES SIX FILTERED FUNCTIONS
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE

Restrictions/Controls & Freight Information | NSN 5915-00-081-9939

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:DMunitions List Item or Commerce Control List Item. Demilitarization required. Total destruction of the item and components so as to preclude restoration or repair to a usable condition by melting, cutting, tearing, scratching, crushing, breaking, punching, neutralizing, etc. (As an alternate, burial or deep water dumping may be used when coordinated with the DoD Demilitarization Program Office.)
Controlled Inventory Item Code:7NON-SENSITIVE (SRC-N/A) - UNCLASSIFIED AA&E: OR ITEMS ASSIGNED A DEMILITARIZATION CODE OTHER THAN A, B, Q, OR P FOR WHICH ANOTHER CIIC IS INAPPROPRIATE. (NOTE: THE LOSS, THEFT, UNLAWFUL DISPOSITION, AND/OR RECOVERY OF AN ITEM WITH CIIC 7 WILL BE INVESTIGATED IN ACCORDANCE WITH DOD-4000-25-2-M AND DOD 7200.14-R, VOLUME 12, CHAPTER 7).
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code BD U.S. Army Aviation and Missile Command
Redstone Arsenal, AL 35898-5230
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable