Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-00-232-2942 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: M15733/04-0008, M15733040008, M1573340008, M15733-4-0008, MI573304008, MI5733-04-008, MILF157334, MILF15733-4, RF032868, RF03286-8, RF32868, RF3286-8, FL53LD3KA1, 1556092, 155609-2, 5915-00-232-2942, 00-232-2942, 5915002322942, 002322942

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 28 OCT 1970 00-232-2942

Drawings & Photos | NSN 5915-00-232-2942


Cross Reference | NSN 5915-00-232-2942

Part Number Cage Code Manufacturer
155609-2 21877 NORTHROP GRUMMAN SYSTEMS CORPORATION DIV NAVAL AND MARINE SYSTEMS
FL53LD3KA1 11872 GULTON INDUSTRIES INC STANDARD ELECTRONICS DIV
FL53LD3KA1 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M15733-4-0008 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
M15733/04-0008 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MI5733-04-008 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
MILF15733-4 81349 MILITARY SPECIFICATIONS PROMULGATED BY MILITARY
RF03286-8 13619 EMS DEVELOPMENT CORPORATION
RF3286-8 13619 EMS DEVELOPMENT CORPORATION

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-232-2942

Technical Data | NSN 5915-00-232-2942

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS BLANK
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS BLANK
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 125.0 VOLTS AC BLANK AND 400.0 VOLTS DC BLANK
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 BLANK
OPERATING CURRENT RATING PER FUNCTION IN AMPS 30.0 BLANK
MAXIMUM VOLTAGE DROP PER FUNCTION 500.0 MILLIVOLTS AC BLANK
INCLOSURE TYPE ENCASED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 THREADED STUD INPUT 1 THREADED STUD OUTPUT
STYLE DESIGNATOR 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 4.969 INCHES MAXIMUM
BODY LENGTH 3.190 INCHES MINIMUM AND 3.310 INCHES MAXIMUM
BODY HEIGHT 2.188 INCHES MINIMUM AND 2.312 INCHES MAXIMUM
BODY WIDTH 2.063 INCHES MINIMUM AND 2.187 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 2 UNTHREADED HOLE
UNTHREADED MOUNTING HOLE DIAMETER 0.187 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 3.859 INCHES MINIMUM AND 3.891 INCHES MAXIMUM
TEST DATA DOCUMENT 81349-MILF15733 SPECIFICATION AND 81349-MILF15733/4 SPECIFICATION
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE BLANK
III MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE 150.0 VOLTS AT SEA LEVEL
III VIBRATION RESISTANCE RANGE IN HERTZ 10.0 TO 55.0
III OPERATING TEMP RANGE -65.0 TO 85.0 DEG CELSIUS
MANUFACTURERS CODE 81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE MILF15733-4
MANUFACTURERS CODE 81349
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE M15733/04-0008

Restrictions/Controls & Freight Information | NSN 5915-00-232-2942

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-00-232-2942

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each