Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-00-350-8196 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: SC591500131, SC5915-0013-1, F15536, RF12054, 5003 4214-2, 5915-00-350-8196, 00-350-8196, 5915003508196, 003508196, 500342142

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 25 MAR 1970 00-350-8196

Drawings & Photos | NSN 5915-00-350-8196


Demand History | NSN 5915-00-350-8196

Part Number Request Date QTY Origin
F15536 2023-11-332 9 DIBBS
RF12054 2023-11-332 9 DIBBS
F15536 2022-06-158 1 DIBBS
RF12054 2022-06-158 1 DIBBS
F15536 2020-11-307 1 DIBBS
RF12054 2020-11-307 1 DIBBS
F15536 2020-10-296 1 DIBBS
RF12054 2020-10-296 1 DIBBS
5915-00-350-8196 2009-09-257 2 DIBBS
5915-00-350-8196 2009-09-257 4 DIBBS

Cross Reference | NSN 5915-00-350-8196

Part Number Cage Code Manufacturer
5003 4214-2 13050 SPECTRUM CONTROL, INC. DIV API TECHNOLOGIES - EIS/WESSON
F15536 0AM43 LCR ELECTRONICS, INC.
RF12054 13619 EMS DEVELOPMENT CORPORATION
SC5915-0013-1 12115 DRS ICAS, LLC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-00-350-8196

Technical Data | NSN 5915-00-350-8196

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 115.0 VOLTS AC 1ST RADIO INTERFERENCE 115.0 VOLTS AC 2ND RADIO INTERFERENCE 28.0 VOLTS DC 4TH RADIO INTERFERENCE 28.0 VOLTS DC 5TH RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 1ST RADIO INTERFERENCE 400.0 2ND RADIO INTERFERENCE 400.0 3RD RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 2.0 1ST RADIO INTERFERENCE 2.0 2ND RADIO INTERFERENCE 2.0 3RD RADIO INTERFERENCE 4.0 4TH RADIO INTERFERENCE 1.5 5TH RADIO INTERFERENCE
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 5 TAB, SOLDER LUG OUTPUT 3 TAB, SOLDER LUG GROUND
STYLE DESIGNATOR 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 3.250 INCHES NOMINAL
BODY LENGTH 2.500 INCHES NOMINAL
BODY HEIGHT 2.500 INCHES NOMINAL
BODY WIDTH 3.000 INCHES NOMINAL
MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH 1.625 INCHES NOMINAL
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.625 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.138 INCHES
TEST DATA DOCUMENT 12115-SC5915-0013-1 DRAWING
III INPUT TERMINAL MANUFACTURER CODE 12115
III INPUT TERMINAL IDENTIFICATION MS3116F12-10S
III VIBRATION RESISTANCE RANGE IN HERTZ 10.0 TO 500.0
III OPERATING TEMP RANGE -65.0 TO 125.0 DEG CELSIUS
III BODY MATERIAL METAL
III BODY SURFACE TREATMENT TIN

Restrictions/Controls & Freight Information | NSN 5915-00-350-8196

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:UPrecious metal type is unknown
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-00-350-8196

Category Code Description
Budget Code9 General Support DIV57X4921.070:Air Force decentrally managed expense items (ERRC XB3, XF-3) with a unit cost of less than $250,000 that are requisitioned/procured at base (retail) level from DLA, GSA, Army, Navy, Depot Maintenance Service, Air Force Industrial Fund (AFMC), local manufacture and commercial vendors.
Materiel Management Aggregation CodeEHSX:ELECTRONIC COMPONENTS
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityPStock Fund (except Munitions)
Acquisition Advice CodesJNOT STOCKED, CENTRALLY PROCURED # (NON-STOCKED ITEMS) IMM/Service centrally managed but not stocked item. Procurement will be initiated only after receipt of a requisition.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each