NSN 5915-01-038-7806 NT10000MOD, NT1000MOD, NT-1000MOD
Product Details | BAND SUPPRESSION FILTER
5915-01-038-7806 An item designed to suppress frequencies within a specified range (band) and to pass frequencies outside the range (band). Excludes a single inductance, a single capacitance, or a single resistance. See COIL (as modified); CAPACITOR (as modified); and RESISTOR (as modified).
Part Alternates: NT10000MOD, NT1000MOD, NT-1000MOD, 32-106960-1, 5915-01-038-7806, 01-038-7806, 5915010387806, 321069601, 010387806
Electrical and Electronic Equipment Components | Filters and Networks
| Supply Group (FSG) | NSN Assign. | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 59 | 11 APR 1977 | 01-038-7806 | 00210 ( FILTER, BAND SUPPRESSION ) |
Request a Quote
What Our Customers Say
Compare
NSNs for Compare ( up to 4 ): Add 5915-01-038-7806
Related Products | NSN 5915-01-038-7806
Technical Data | NSN 5915-01-038-7806
| Characteristic | Specifications |
|---|---|
| REFERENCE FREQUENCY PER FUNCTION | 1.0 KILOHERTZ BLANK |
| INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 1.0 BLANK |
| FREQUENCY BAND WIDTH PER FUNCTION | 997.00 HERTZ BLANK AND 1.003 KILOHERTZ BLANK |
| SOURCE IMPEDANCE RATING PER FUNCTION | 100.0 KILOHMS BLANK |
| LOAD IMPEDANCE PER FUNCTION | 100.0 KILOHMS BLANK |
| INCLOSURE TYPE | HERMETICALLY SEALED |
| FUNCTIONAL TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD INPUT 2 WIRE LEAD OUTPUT |
| STYLE DESIGNATOR | 2 RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
| OVERALL HEIGHT | 1.625 INCHES NOMINAL |
| BODY LENGTH | 1.250 INCHES NOMINAL |
| BODY HEIGHT | 0.625 INCHES NOMINAL |
| BODY WIDTH | 1.000 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 4 TERMINAL |
| III SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 994.00 HERTZ BLANK AND 997.00 HERTZ BLANK AND 1.003 KILOHERTZ BLANK AND 1.006 KILOHERTZ BLANK |
| III DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 3.0 MINIMUM BLANK AND 30.0 MAXIMUM BLANK |
| III PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE BLANK |
| III OPERATING TEMP RANGE | -0.0 TO 50.0 DEG CELSIUS |
| III BODY MATERIAL | METAL |
Restrictions/Controls & Freight Information | NSN 5915-01-038-7806
| Category | Code | Description |
|---|---|---|
| Shelf-Life Code: | 0 | Nondeteriorative |
| Hazardous Material Indicator Code | P | There is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product |
| Demilitarization Code: | A | Non-Munitions List Item/ Non-Strategic List Item - Demilitarization not required. |
| Controlled Inventory Item Code: | U | UNCLASSIFIED |
| Precious Metals Indicator Code: | A | Item does not contain precious metal |
| Criticality Code: | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
| Automatic Data Processing Equipment: | 0 | Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9) |
| Category | Code | Description |
|---|---|---|
| NMF Description | 061990 | ELECTRICAL EQUIP:FILTERS |
| Less than car load rating | ||
| Less than truck load rating | P | 77.5 |
| Water commodity Code | 72D | unknown |
| Originating Activity Code | TX | Defense Supply Center Columbus Columbus, OH 43218 |
| Air Dimension Code | A | Shipment is not a consolidation and does not exceed 72 inches in any dimension. |
| Air Commodity | H | Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc. |
| Air Special Handling | Z | No special handling required. |
| Special Handling Code | 9 | unknonwn |
| HAZMAT | ||
| Type of Cargo | Z | No special type of cargo code applicable |
Management | NSN 5915-01-038-7806
| Category | Code | Description |
|---|---|---|
| Cognizance Codes | 9B | Navy-owned stocks of DLA material Naval Inventory Control Point, Mechanicsburg |
| Source of Supply | SMS | Defense Logistics Agency Enterprise Business Systems |
| Agency | DN | Department of the Navy |
| Service Organization | N | U.S. Navy |
| Acquisition Advice Codes | Z | INSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures. |
| Controlled Item Code | U | UNCLASSIFIED |
| Shelf Life Code | 0 | Nondeteriorative |
| Purchasing | QTY UOM |
1 EA : Each |