Product Details | RADIO FREQUENCY INTERFERENCE FILTER

5915-01-152-5060 An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes FILTER, LOW PASS and SUPPRESSOR, IGNITION INTERFERENCE. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see FILTER, BAND SUPPRESSION and FILTER, BAND PASS. See also LIMITER, ELECTRICAL NOISE.

Part Alternates: F212022, F-21202-2, FC2633, JN102948A, JN10-2948A, RMEF0156, RME-F-0156, 71178282, 7117828-2, 9440224A, 9440-224A, 5915-01-152-5060, 01-152-5060, 5915011525060, 011525060

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 04 MAY 1983 01-152-5060

Drawings & Photos | NSN 5915-01-152-5060


Cross Reference | NSN 5915-01-152-5060

Part Number Cage Code Manufacturer
7117828-2 06481 NORTHROP GRUMMAN SYSTEMS CORPORATION
7117828-2 17863 LITTON SYSTEMS INC GUIDANCE AND CONTROL SYSTEMS DIV
9440-224A 16546 MEPCO/CENTRALAB A NORTH AMERICAN PHILIPS CO
9440224A 33095 SPECTRUM CONTROL, INC. DBA API TECHNOLOGIES
F-21202-2 96733 SFE TECHNOLOGIES
FC2633 56528 FIL-COIL (FC) INC.
JN10-2948A 13619 EMS DEVELOPMENT CORPORATION
JN10-2948A 56289 SPRAGUE ELECTRIC CO WORLD HQS
RME-F-0156 0S2B1 RME FILTERS INC

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-152-5060

Technical Data | NSN 5915-01-152-5060

Characteristic Specifications
SOURCE IMPEDANCE RATING PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE
LOAD IMPEDANCE PER FUNCTION 50.0 OHMS 1ST RADIO INTERFERENCE 50.0 OHMS 2ND RADIO INTERFERENCE 50.0 OHMS 3RD RADIO INTERFERENCE
OPERATING VOLTAGE RATING AND TYPE PER FUNCTION 240.0 VOLTS AC 1ST RADIO INTERFERENCE 240.0 VOLTS AC 2ND RADIO INTERFERENCE 240.0 VOLTS AC 3RD RADIO INTERFERENCE
POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ 400.0 1ST RADIO INTERFERENCE 400.0 2ND RADIO INTERFERENCE 400.0 3RD RADIO INTERFERENCE
OPERATING CURRENT RATING PER FUNCTION IN AMPS 10.0 1ST RADIO INTERFERENCE 10.0 2ND RADIO INTERFERENCE 10.0 3RD RADIO INTERFERENCE
MAXIMUM VOLTAGE DROP PER FUNCTION 500.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE 500.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE 500.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE
INCLOSURE TYPE HERMETICALLY SEALED
FUNCTIONAL TERMINAL TYPE AND QUANTITY 1 CONNECTOR, RECEPTACLE INPUT 3 TURRET OUTPUT 1 TURRET GROUND
STYLE DESIGNATOR 5 RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES
OVERALL LENGTH 4.390 INCHES NOMINAL
BODY LENGTH 3.190 INCHES MAXIMUM
BODY HEIGHT 2.120 INCHES NOMINAL
BODY WIDTH 2.750 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY 4 THREADED HOLE
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH 1.875 INCHES NOMINAL
MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR UNC
NOMINAL THREAD SIZE 0.112 INCHES
SPECIAL FEATURES THREE FILTERED FUNCTIONS
III PRINCIPAL CIRCUITRY TYPE PER FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
III MAXIMUM TEMP RISE 25.0 DEG CELSIUS
III INPUT TERMINAL MANUFACTURER CODE 96906
III INPUT TERMINAL IDENTIFICATION MS3102R-20-4P
III OPERATING TEMP RANGE -55.0 TO 85.0 DEG CELSIUS
III BODY SURFACE TREATMENT TIN

Restrictions/Controls & Freight Information | NSN 5915-01-152-5060

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:ANon-Munitions List Item/ Non-Strategic List Item - Demilitarization not required.
Controlled Inventory Item Code:UUNCLASSIFIED
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 72D unknown
Originating Activity Code TX Defense Supply Center Columbus
Columbus, OH 43218
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo Z No special type of cargo code applicable

Management | NSN 5915-01-152-5060

Category Code Description
Cognizance Codes9BNavy-owned stocks of DLA material
Naval Inventory Control Point, Mechanicsburg
Source of SupplySMSDefense Logistics Agency
Enterprise Business Systems
AgencyDNDepartment of the Navy
Service OrganizationNU.S. Navy
Acquisition Advice CodesZINSURANCE/NUMERIC STOCKAGE OBJECTIVE ITEM # Items which may be required occasionally or intermittently, and prudence requires that a nominal quantity of materiel be stocked due to the essentiality or the lead time of the item. 1. The item is centrally managed, stocked, and issued. 2. Requisitions will be submitted in accordance with IMM/Service requisitioning procedures.
Controlled Item CodeUUNCLASSIFIED
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each