Product Details | ELECTRICAL FILTER ASSEMBLY

5915-01-176-8585 Two or more electrical filters on a common mounting or mounted on each other. Does not include coils, capacitors or resistors alone.

Part Alternates: 814498-802, 5915-01-176-8585, 01-176-8585, 5915011768585, 814498802, 011768585

Electrical and Electronic Equipment Components | Filters and Networks

Supply Group (FSG) NSN Assign. NIIN
59 17 APR 1984 01-176-8585

Cross Reference | NSN 5915-01-176-8585

Part Number Cage Code Manufacturer
814498-802 37695 RAYTHEON COMPANY DBA RAYTHEON

Request a Quote

What Our Customers Say

Compare

NSNs for Compare ( up to 4 ): Add 5915-01-176-8585

Technical Data | NSN 5915-01-176-8585

Characteristic Specifications
FILTER TYPE BAND PASS
SPECIAL FEATURES CONTAINS 8 FILTER COILS, 2 MODIFIED CONNECTORS, 4 VARIABLE AIR DIELECTRIC CAPACITORS, 1 END PLATE, 1 COVER PLATE, 1 FILTER HOUSING
III END ITEM IDENTIFICATION AN/ALM-231 WATTS
MANUFACTURERS CODE 37695
DESIGN CONTROL REFERENCE 814498-802

Restrictions/Controls & Freight Information | NSN 5915-01-176-8585

Category Code Description
Shelf-Life Code:0Nondeteriorative
Hazardous Material Indicator CodePThere is no information in the HMIS; however, the NSN is in an FSC in Table II of Federal Standard 313 and an MSDS may be required by the user. The requirement for an MSDS is dependent on a hazard determination of the supplier or the intended end use of the product
Demilitarization Code:PMunitions List Item. Demilitarization required. Security classified item - Declassification and any additional demilitarization and removal of any sensitive markings or information will be accomplished prior to accountability or physical transfer to a DRMO. This code will not be assigned to AEDA items.
Controlled Inventory Item Code:CCONFIDENTIAL OR MODERATE SENSITIVITY (SRC III) AND LOW SENSITIVITY (SRC IV) - CONFIDENTIAL AA&E. (ITEM WILL BE STORED AND TRANSPORTED IN ACCORDANCE WITH THE PROVISIONS OF DOD 5100.76M OR DOD 5200.1R INFORMATION SECURITY PROGRAM - WHICHEVER IS MORE STRINGENT)./
Precious Metals Indicator Code:AItem does not contain precious metal
Criticality Code:X The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
Automatic Data Processing Equipment:0Represents items with no ADP components. NOTE: Codes 1 through 6 are only to be used when the item is Automatic Data Processing Equipment (ADPE) in its entirety and is limited to the type meeting only one of the definitions for codes 1 through 6. (See code 9)
Category Code Description
NMF Description 061990 ELECTRICAL EQUIP:FILTERS
Less than car load rating
Less than truck load rating P 77.5
Water commodity Code 738 unknown
Originating Activity Code TG Warner-Robins Air Logistics Center
Robins AFB, GA 31098-5609
Air Dimension Code A Shipment is not a consolidation and does not exceed 72 inches in any dimension.
Air Commodity H Signal Corps supplies and equipment, including radio equipment and supplies, communications equipment and supplies, electrical equipment and supplies, etc.
Air Special Handling Z No special handling required.
Special Handling Code 9 unknonwn
HAZMAT
Type of Cargo 3 Electrostatic Sensitive Device (ESD), subject to damage caused by electrostatic discharge. (See DoD 4500.32-R, Volume 1, Appendix A, Section I for additional information on ESD devices).

Management | NSN 5915-01-176-8585

Category Code Description
Materiel Management Aggregation CodeEWTG:AIRBORNE ELECTRONIC WARFARE EQUIPMENT
Price ValidationN The current standard price in Catalog Management Data (CMD) has not analyzed or coded for LP/LM.
  • The price has not been analyzed or reviewed for accuracy.
  • ZOP or Standard price challenges are permissible, but must be supported with adequate justification. However, if coded for Local Purchase (LP) or Fabrication/Manufacture as indicated with an (LM) Acquisition Advice Code of ?L? or?F?,the case must be evaluated locally where purchased or fabricated.
Fund CodeSFStock fund applicable to items managed for the Air Force by the respective Inventory Control Point.
Source of SupplyFLZWarner Robins Air Logistics Center
Robins AFB, GA 31098-5609
AgencyDFDepartment of the Air Force
Service OrganizationFU.S. Air Force
ReparabilityNStock Fund (except Munitions)
Acquisition Advice CodesDDoD INTEGRATED MATERIEL-MANAGED, STOCKED, AND ISSUED # Issue, transfer, or shipment is not subject to specialized controls other than those imposed by the Integrated Materiel Manager/Service supply policy. 1. The item is centrally managed, stocked, and issued. 2. Requisitions must contain the fund citation required to acquire the item. Requisitions will be submitted in accordance with Integrated Materiel Manager(IMM)/Service requisitioning procedures.
Controlled Item CodeCCONFIDENTIAL OR MODERATE SENSITIVITY (SRC III) AND LOW SENSITIVITY (SRC IV) - CONFIDENTIAL AA&E. (ITEM WILL BE STORED AND TRANSPORTED IN ACCORDANCE WITH THE PROVISIONS OF DOD 5100.76M OR DOD 5200.1R INFORMATION SECURITY PROGRAM - WHICHEVER IS MORE STRINGENT).
Shelf Life Code0Nondeteriorative
Purchasing QTY
UOM
1
EA : Each